Ventilation Mode Parameters - Honeywell HVC0001 Owner's Manual

Programmable bath fan control
Hide thumbs Also See for HVC0001:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Guide 400-305-000-EFS
Set the Ventilation Mode parameters
At first power-up, you will be prompted to set the following parameters:
Set no. of
Select Units
(US /Metric)
Bedrooms *
If you press the main button for 3 seconds or do
not press any button for 60 seconds, the
controller will go to normal display. If the
parameters are not set, you will again be
prompted the next time the controller is powered
up, for example, after a power outage. The
parameters can be set at any time (see page 10).
Set Floor Size **
Set Fan Capacity ***
(Sq. ft or Sq. M)
(CFM or LPS)
*
**
*** Fan capacity (30, 40, ..., 200 CFM or 15, 20, ..., 100 LPS)
**** The controller shows whether you pass or fail ASHRAE
6
ASHRAE 62.2
Pass/Fail ****
No. of bedrooms (1, 2, ..., 6)
Floor space (1000, 1100, ..., 5000 sq. ft. or 100, 110, ..., 500 m
Standard 62.2 for ventilation and the percentage of time the fan
will run every hour. If the controller indicates Fail; this usually
means the fan capacity is insufficient for your house.
Normal
Display
2
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvc0002

Table of Contents