Special Features - Sharp LC-26AF3 M/H/X Service Manual

Table of Contents

Advertisement

7
[RGB]
1
RGB ADJ
2
R GAIN
3
G GAIN
4
B GAIN
5
R OFFSET
6
G OFFSET
7
B OFFSET
8
[TUNER]
1
TUNER TEST
9
[M GAMMA INFO]
1
MGAMMA IN 1
2
MGAMMA IN 2
3
MGAMMA IN 3
4
MGAMMA IN 4
5
MGAMMA IN 5
6
MGAMMA IN 6
7
MGAMMA IN WRITE
8
MGAMMA IN RESET
10
[M GAMMA 1-3]
1
MGAMMA R 1
2
MGAMMA G 1
3
MGAMMA B 1
4
MGAMMA R 2
5
MGAMMA G 2
6
MGAMMA B 2
7
MGAMMA R 3
8
MGAMMA G 3
9
MGAMMA B 3
10
MGAMMA WRITE
11
[M GAMMA 4-6]
1
MGAMMA R 4
2
MGAMMA G 4
3
MGAMMA B 4
4
MGAMMA R 5
5
MGAMMA G 5
6
MGAMMA B 5
7
MGAMMA R 6
8
MGAMMA G 6
9
MGAMMA B 6
10
MGAMMA WRITE
12
[ETC]
1
EEP SAVE
2
EEP RESTORE
3
STANDBY CAUSE RESET
4
AUTO INSTALLATION SW
5
SYS MODEL COUNTRY

6. Special features

`
STANDBY CAUSE (Page 1/12)
To indicate the reason code when the unit last enters standby.
When the unit enters standby, the cause of the error is recorded on EEPROM as much as possible.
When repairing a defective unit, checking adjustment values may useful for detecting abnormalities.
EEP SAVE (Page 12/12)
`
Storage of EEP adjustment value
EEP RECOVER (Page 16/16)
`
Retrieval of EEP adjustment value from storage area
Saving adjustment values
Restoring adjustment values
Selecting region
25
LC-26AF3 M/H/X
LC-32AF3 M/H/X
LC-37AF3 M/H/X
W/B adjustment
EEP writing of adjustment values
Initialization of adjustment values
EEP writing of adjustment values
EEP writing of adjustment values
Writing adjustment values in the storage area
Writing back stored adjustment values
Displaying selected regions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32af3 m/h/xLc-37af3 m/h/x