Napoleon Bayfield GDS25P Installation And Operation Instructions Manual page 13

Napoleon fireplaces installation and operation instructions gds25n, gds25p
Table of Contents

Advertisement

when (H
) < (V
)
T
T
FIGURE 9
See graph to determine the required vertical rise V
required horizontal run H
.
T
REQUIRED VERTICAL RISE
IN FEET (V
)
T
The shaded area within the lines represents acceptable
values for H
and V
.
T
T
For vent confi gurations requiring more than one 45º and one
90° elbow , the following formulas apply:
Formula 1: H
< V
T
Formula 2: H
+ V
T
T
VERTICAL TERMINATION
45°
for the
T
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
5
10
15
HORIZONTAL VENT RUN
PLUS OFFSETS IN FEET
T
< 40 feet
Example 3:
FIGURE10
45°
H
1
V
= 5 ft
1
V
= 10 ft
2
V
= V
+ V
= 5 + 10 = 15 ft
T
1
2
H
= 3 ft
1
H
= 2.5 ft
2
H
= H
+ H
= 3 + 2.5 = 5.5 ft
R
1
2
H
= .03(one 45º elbow + three 90º elbows - 135º)
O
= .03(45+90+90+90-135)=5.4
H
= H
+ H
= 5.5 + 5.4 = 10.9 ft
T
R
O
H
+ V
= 10.9 + 15 = 25.9 ft
T
T
H
< V
Formula 1:
T
10.9 < 15
H
+ V
20
Formula 2:
T
T
25.9 < 40
Since both formulas are met, this vent confi guration is
acceptable.
V
2
90°
H
2
90°
V
1
90°
T
< 40 feet
W415-0547 / C / 07.25.06
13