2004.11.12
SPECIFICATIONS
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
ELECTRICAL DATA
POWER SOURCE
FREQUENCY
RUNNING CURRENT
(A)
INPUT WATTS
(kW)
E.E.R.
(kW/kW)
MOISTURE REMOVAL
AIR CIRCULATION-Hi
COMPRESSOR
TYPE
DISCRIMINATION
REFRIGERANT
R410A
FAN MOTOR
POWER SOURCE
DISCRIMINATION
HI-SPEED
INDOOR UNIT
MED-SPEED (r.p.m.)
LO-SPEED
QUIET
DISCRIMINATION
OUTDOOR UNIT
DIMENSIONS
INDOOR UNIT
H x W x D
OUTDOOR UNIT
H x W x D
WEIGHT
INDOOR UNIT
GROSS / NET
OUTDOOR UNIT
GROSS / NET
COOL & HEAT
AWY24LBAJ
AOY24LMAL
(kW)
6.8
(kW)
7.0
(V)
(Hz)
COOLING
9.3
HEATING
8.5
COOLING
2.12
HEATING
1.94
COOLING
3.21
HEATING
3.61
( /hr)
3.0
(m
/hr)
1,050
3
Hermetic type, Inverter, 4 poles,
Three phase, DC motor, Twin Rotary
TNB220FPCM9
(g)
(V)
MFD-36JO
(r.p.m.)
(r.p.m.)
(r.p.m.)
MFB-30NTAT
(r.p.m.)
(mm)
270 x 1,150 x 285
(mm)
900 x 900 x 350
(kg)
(kg)
1
COOL & HEAT
AWY30LBAJ
AOY30LMAL
8.0
8.5
230
50
13.3
12.3
3.04
2.81
2.68
3.02
3.6
1,050
1,850
230
1,450
1,280
1,180
1,080
730
20 / 16
78 / 70