Installation Ii (Wooden Header Installation) - Panasonic fv-20vq3 Installation Instructions Manual

Ventilating fan
Table of Contents

Advertisement

INSTALLATION II (WOODEN HEADER)
1.
Install header between ceiling joists using nails or
screws. (Fig. 5)
2.
Install the ventilating fan to the header with long screws.
(Figs. 5 & 6)
Model No.
FV-20VQ3
FV-30VQ3
FV-40VQ3
3.
Insert the circular duct to the adapter.
Remove the junction box cover and secure conduit to
junction box knockout hole. (7/8 inch) (Fig. 6)
4.
Refer to wiring diagram.
Using wire nuts, connect house power wires to ventilat-
ing fan wires: black to black; white to white; green to
green. Replace junction box cover.
CAUTION
Mount junction box cover carefully so that lead
wires are not pinched.
Wiring Diagram
Motor
Thermal Cut Off
White
Red
Black
5.
Finish ceiling work. Ceiling hole should be aligned with
the edge of the flange. (Fig. 7)
6.
Mount grille to fan body. (Fig. 4 of page 5).
Panasonic_E
mm (inch)
A
B
315
454
(12 13/32)
(17 7/8)
380
518
(15)
(20 13/32)
White
White
Live
Power Supply
AC120V 60Hz
Capacitor
Black
Black
Neutral
Green
Green
Earth
Page 6
Ceiling joist
Ventilating fan
Long screw
Ceiling
Flange
6
19/02/02, 11:25 AM
Header
Ceiling joist
Adapter
Fig. 5
Adapter
Circular duct
Junction box cover
Fig. 6
Fig. 7
Adobe PageMaker 6.5C/PPC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv-30vq3Fv-40vq3

Table of Contents