Advertisement

technical data

Concealed Ceiling Unit
FXSQ-P7VEB

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXSQ-P7VEB

  • Page 1: Technical Data

    Concealed Ceiling Unit FXSQ-P7VEB...
  • Page 2 Concealed Ceiling Unit FXSQ-P7VEB...
  • Page 3: Table Of Contents

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB TABLE OF CONTENTS FXSQ-P7VEB Specifications ............2 Technical Specifications .
  • Page 4: Specifications

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Specifications ® t e m U n i l e d 7 V E S y s o o r c e a Q - P I n d C o n...
  • Page 5 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Specifications 1-1 TECHNICAL SPECIFICATIONS FXSQ20P7VEB FXSQ25P7VEB FXSQ32P7VEB FXSQ40P7VEB FXSQ50P7VEB Decoration Panel Model BYBS32DJW1 BYBS32DJW1 BYBS32DJW1 BYBS45DJW1 BYBS45DJW1 Colour White (10Y9/0,5) Dimensions Height Width Depth Weight Drain-up Height Air Filter Resin net with mold resistance...
  • Page 6 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Specifications 1-1 TECHNICAL SPECIFICATIONS FXSQ63P7VEB FXSQ80P7VEB FXSQ100P7VEB FXSQ125P7VEB Motor Speed (cooling) High 1,161 1,060 1,218 Speed (heating) High 1,161 1,060 1,218 Motor Output (high) Drive Direct drive Refrigerant Name R-410A Sound level...
  • Page 7: Electrical Specifications (50Hz)

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Specifications 1-2 ELECTRICAL SPECIFICATIONS (50HZ) FXSQ20P7VEB FXSQ25P7VEB FXSQ32P7VEB FXSQ40P7VEB FXSQ50P7VEB Power Supply Name Frequency Voltage 220-240 Current Minimum circuit amps (MCA) Maximum fuse amps (MFA) Voltage range Minimum -10% Maximum +10%...
  • Page 8: Electrical Data

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Electrical data FXSQ-P Units Power supply Model Type Volts Min. Max. FXSQ20 FXSQ25 FXSQ32 FXSQ40 220~240V / FXSQ50 50/60 -10% +10% 220V FXSQ63 FXSQ80 FXSQ100 FXSQ125 SYMBOLS NOTES MCA: Min. Circuit Amps (A)
  • Page 9: Safety Device Settings

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Safety device settings Safety devices PC Board Fuse 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A PC Board Fuse (Fan Driver)
  • Page 10: Capacity Tables

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Capacity tables 5 - 1 Cooling capacity tables FXSQ-P7 TC: Total Capacity: kW ; SHC: Sensible heat capacity: kW Indoor air temperature Outdoor 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 11 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Capacity tables 5 - 1 Cooling capacity tables FXSQ-P7 TC: Total Capacity: kW ; SHC: Sensible heat capacity: kW Indoor air temperature Outdoor 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 12: Heating Capacity Tables

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Capacity tables 5 - 2 Heating capacity tables FXSQ-P7 Indoor air temperature: °CDB Outdoor 18.0 21.0 24.0 air temp. Unit size 16.0 20.0 22.0 °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 13 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Capacity tables 5 - 2 Heating capacity tables FXSQ-P7 Indoor air temperature: °CDB Outdoor air temp. Unit Size 16.0 18.0 20.0 21.0 22.0 24.0 °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 14: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXSQ20-32P View A-A Detail B Suspension bolt Detail B (Service space) (Suspension position) NOTE Name Description Liquid pipe connection ø 6.35 flare (connection) Refer to ‘outlook drawing for installing optional accessories’...
  • Page 15 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXSQ63-80P View A-A Detail B Suspension bolt Detail B or more (Service space) (Suspension position) NOTE Name Description Liquid pipe connection ø...
  • Page 16: Centre Of Gravity

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Dimensional drawing & centre of gravity 6 - 2 Centre of gravity FXSQ20-125P MODEL FXSQ20~32 FXSQ40,50 FXSQ63,80 1000 FXSQ100,125 1400 4TW31189-1A ® • VRV Systems • Indoor Units...
  • Page 17: Piping Diagram

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Piping diagram FXSQ20-125P Refrigerant flow Heat exchanger Cooling Heating Refrigerant pipe connection port diameters Model Liquid FXSQ20,25,32,40,50 Ø12.70 Ø6.35 FXSQ63,80,100,125 Ø15.90 Ø9.52 Liquid pipe connection port Filter Filter Electronic expansion valve...
  • Page 18: Wiring Diagram

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Wiring diagram 8 - 1 Wiring diagram FXSQ-P Indoor 1N~220-240V 50Hz 1N~220V 60Hz Input from outside note 3 Transmission wiring Central remot control note 2 For 60~125 class (71~140 class) For 20~50 class...
  • Page 19: Sound Data

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Sound data 9 - 1 Sound pressure spectrum FXSQ20-25P FXSQ32P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31187-2 3TW31207-2 Notes Notes Data is valid at free field condition...
  • Page 20 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Sound data 9 - 1 Sound pressure spectrum FXSQ80P FXSQ100P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31247-2 3TW31257-2 Notes Notes Data is valid at free field condition...
  • Page 21: Sound Power Spectrum

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Sound data 9 - 2 Sound power spectrum FXSQ20-25P FXSQ32P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31187-1 3TW31207-1 Notes Notes dBA = A-weighted sound power level. (A-scale according to IEC) dBA = A-weighted sound power level.
  • Page 22 • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Sound data 9 - 2 Sound power spectrum FXSQ80P FXSQ100P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31247-1 3TW31257-1 Notes Notes dBA = A-weighted sound power level. (A-scale according to IEC) dBA = A-weighted sound power level.
  • Page 23: Fan Characteristics

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Fan characteristics FXSQ20-25P Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP H (max. ESP) (max. ESP) Upper limit of ESP Upper limit of ESP by airflow auto adjustment M (max.
  • Page 24: 10 Fan Characteristics

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Fan characteristics FXSQ40-50 Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) H (max. ESP) Upper limit of ESP Upper limit of ESP (max. ESP) Upper limit of ESP by airflow auto adjustment Lower limit of ESP M (max.
  • Page 25: 10 Fan Characteristics

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Fan characteristics FXSQ80P7 Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP H (max. ESP) Upper limit of ESP (max. ESP) Upper limit of ESP by M (max. ESP)
  • Page 26: 10 Fan Characteristics

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Fan characteristics FXSQ125P Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) H (max. ESP) Upper limit of ESP (max. ESP) Upper limit of ESP Upper limit of ESP by Lower limit of ESP airflow auto adjustment M (max.
  • Page 27: Installation

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Installation 11 - 1 Installation method FXSQ- P Rear Suction Bottom Suction Ceiling return Ceiling return Drain pump up height Direct installation of inlet panel Installation with duct Wide variety of installation methods...
  • Page 28: Filter Installation Method

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Installation 11 - 2 Filter installation method FXSQ- P (or less) Installation without air inlet duct Installation with air inlet duct OTES Description When installing the unit with rear Suspended Ceiling...
  • Page 29: Switch Box Connection

    • Indoor Units • CONCEALED CEILING UNIT • FXSQ-P7VEB Installation 11 - 3 Switch box connection FXSQ20-125P Emerg. Norm. Common power supply 3TW31184-5 ® • VRV Systems • Indoor Units...
  • Page 31 Specifications are subject to change without environment. This challenge demands the eco design prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or and development of a wide range of products and an indirect damage, in the broadest sense, arising from or related to the use energy management system, resulting in energy and/or interpretation of this publication.