Download Print this page

Murphy HD9063 Series Installation And Operation Instructions page 3

Murphy dual set point speed switch installation and operation instructions

Advertisement

CAUTION:
PERFORM THE WIRING OPERATION WITH THE POWER SOURCE "OFF"
1. Connect terminal 5 on the HD9063 to engine ground and
connect terminal 4 to battery positive (see Figure 3).
2. Connect the magnetic pickup cable conductors to terminals
6 and 7.
3. If cable is shielded, connect shield to engine chassis ground.
4. If desired, connect a normally open test push button switch
between terminals 8 and 9.
5. Connect crank disconnect circuit to crank disconnect termi-
nals 1 thru 3 as discussed in Crank Disconnect Relay
Function, page 2. On HD9063-USOS models connect the
overspeed circuits 1 thru 3 as discussed in Overspeed Relay
and Underspeed Relay Function, page 2.
6. Connect the overspeed circuits to overspeed terminals 10 thru
12 as discussed in Overspeed Relay and Underspeed Relay
Function, page 2.
A magnetic pickup is an AC generator. It is normally installed
into the flywheel housing of an internal combustion engine, so
that the starter ring gear acts upon it to generate a voltage pulse
each time a gear tooth passes the end of the sensor.
Magnetic Pickup Installation (see Figure 5)
Drill and tap a hole in the flywheel housing (See Specifications
Chart below for model and thread size). IMPORTANT: Drilling
too deep may damage ring gear teeth. Blow chips with air hose
when drilling and tapping hole.
Gap Adjustment
Insert magnetic pickup and turn until it stops at the face of the gear.
Back-off the gear by turning the pickup counterclock-
wise 1/4, 1/2, or 3/4 turn (Figure 4) .
See Gap Chart (above, right) to determine gap
distance based on the turn. Check gap clear-
ance by rotating the gear completely around.
NOTE: Magnetic pickup gap should be
adjusted so that the minimum voltage required
is attained at the engine's lowest RPM. The
voltage will increase as the speed increases.
If erratic readings occur, remove magnetic
pickup and check the magnetic tip for metal chips.
Murphy Magnetic Pickup Specifications Chart
Pickup
Total
Model
Length
MP3298*
3 in. (76 mm)
MP7906
3 in. (76 mm)
MP7905
††
4-1/2 in. (114 mm)
*
Replaces 20-01-0080 and MP100. Lead wire hookup (12 in. [305 mm]).
Replaces 20-01-0081. Lead wire hookup (12 in. [305 mm]).
††
Replaces 20-01-0082. Lead wire hookup (12 in. [305 mm]).
WIRING
Crank Control
to Shutdown
(HD9063-USOS)
DC Negative
(Engine Ground)
MAGNETIC PICKUP INSTALLATION
1/4
1/2
3/4
Figure 4
Threaded
Thread
Length
Size
3 in. (76 mm)
5/8-18 UNF
3 in. (76 mm)
3/4-16 UNF
4-1/2 in. (114 mm)
3/4-16 UNF
HD-96044N page 3 of 4
1 2 3 4 5 6 7 8 9 10 11 12
K1
To Engine
Common
Circuit
Normally Open
or
Normally Closed
Circuits
DC Positive
From Magnetic Pickup
Gap Chart
THREAD
1/4
SIZE
.013 in.
5/8-18 UNF
(0.33 mm)
.015 in.
3/4-16 UNF
(0.38 mm)
Always use a two-conductor shielded cable. Ground the
shield to a metal frame ground at the engine end only.
Never run these wires
next to spark plug wires
or in wire loom with other
wires carrying inductive
loads or alternating current.
After adjusting,
set locknut.
Drill and tap casing
(see thread sizes in
Specifications).
Gap
(see Gap Chart)
NOTE: Clean gear casing
and magnetic sensor
of metal chips or filings.
(+)
( )
(+)
( )
K2
12
Common
Normally Open
Normally Closed
Test
Pushbutton
Figure 3
TURN
1/2
3/4
.028 in.
.035 in.
.055 in.
(0.71 mm)
(0.88 mm)
(1.39 mm)
.030 in.
.045 in.
.062 in.
(0.76 mm)
(1.14 mm)
(1.57 mm)
Casing
Gear (must be made
of magnetic material).
Figure 5
To
Shutdown
Circuits
1
AC
Meter