Important Safety Information; Warranty Information; Troubleshooting - InSinkErator C1300-SS Installation Manual

Steaming hot water system
Hide thumbs Also See for C1300-SS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

IMPORTANT SAFETY INFORMATION

Use this water heater only for its intended use as described in this manual.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of appliance by a person responsible for their safety. Children should be supervised to ensure that
they do not play with hot water tap. To reduce the risk of injury, close supervision is required when an
appliance is used near children.
Do not operate this product if it has been or appears to be damaged in any manner or after the product
malfunctions, or is dropped. Return the complete product immediately to your retail dealer for inspection, and
if necessary, adjustment or repair.
To reduce the risk associated with choking: Do not allow children under 3 years of age to
have access to small parts during the installation of this product.
Electric Shock Hazard: To reduce the risk of electric shock, do not immerse or expose
the product, flexible cord or plug to rain, moisture or any liquid or when standing in
or on damp or wet surfaces. If any electrical product falls into water, UNPLUG it
immediately. DO NOT REACH INTO THE WATER. Important: Prior to reconnecting to the
power supply, the product should be inspected by a qualified technician.
Personal Injury/Property Damage: To reduce the risk associated with hazardous
voltage due to an installer drilling through existing electric wiring in the area of
installation: Do not install near electric wiring which may be in path of a drilling tool
when selecting the position to mount the system bracket.
Also avoid the risk of drilling into water pipes which may result in property damage.
Important: Always arrange the power cord so that it cannot come in contact with hot surfaces.
Do not disconnect the product from the power supply by pulling on the cord.
Do not use the product for other than its intended use as described in these instructions. The use of accessory
attachments other than those recommended by the manufacturer may cause safety hazards.
The recommended connection may be made to an existing cold water line with a branch terminating with a shutoff
valve, a pressure relief and dual check non-return valve sited adjacent to the product.
Electric Shock Hazard: Using an ungrounded (no earth ground) or improperly
connected appliance can result in serious injury or death from electrical shock.
This appliance must be earthed (grounded). This steaming hot water tap is equipped with a cord that has a
grounding conductor and earth ground pin. The plug must be connected to an appropriate outlet that is properly installed
and earthed (grounded) in accordance with all local codes and ordinances. Do not modify the plug provided with the
appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Check with a qualified
electrician or tradesman if you are in doubt as to whether the steaming hot water tap is properly earthed (grounded).
Personal Injury/Property Damage: This tank is a non-pressurized tank. DO NOT modify
this system. DO NOT close vent tube or connect other types of taps or valves to the tank.
Use only the InSinkErator tap supplied. Use only parts provided. Contact an authorized
InSinkErator Service agent for repairs or replacement components.
To reduce the risk associated with the ingestion of contaminants: Do not use with water
that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system.
A steaming hot water tap, like any water heater, has a limited life and will eventually fail. To avoid possible property
damage and personal injury, this steaming hot water tap should be regularly examined for leakage and/or corrosion
and replaced when necessary. A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should
be used in those applications where any leakage could cause property damage.
Fire Hazard: To minimize possibility of fire, DO NOT store flammable items such as rags,
paper or aerosol cans near the tank. DO NOT store or use petrol or other flammable
vapors and liquids in the vicinity of this or any other appliance.
Leak Hazard: Regularly inspect dispenser and plumbing fittings for leaks, which can
cause property damage and could result in personal injury.
6
Property Damage: To reduce the risk associated with property damage due to water
leakage or flooding, and to ensure optimal performance:
NOTICE
• Read and follow Use Instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
System Requirements (Hot Water Tank, Filtration System and Dispenser):
• The flexible vent and outlet tubes must be correctly connected to the tap supplied by
the manufacturer. They must not be obstructed or connected to a normal type tap or
any other type.
• Do not install on hot water supply lines. The maximum operating water temperature of
this system is 100°F (37.8°C). Attach to cold water supply only.
• Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure
exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a
plumbing professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions
exist you must install a water hammer arrester. Contact a plumbing professional if you
are uncertain how to check for this condition.
• Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
• Protect from freezing, shut off water supply, remove filter cartridge, drain hot water
tank and tubing when temperatures are expected to drop below 40° F (4.4° C); see
Seasonal Storage/Drainage section.
• Do not use a torch or other high temperature sources near system, cartridges, plastic
fittings or plastic plumbing.
• Do not install near water pipes which will be in path of a drilling tool when selecting
the position to mount the bracket.
• Mount system in such a position as to prevent it from being struck by other items used
in the area of installation.
• Ensure that the location and fasteners will support the weight of the system when
installed and full of water.
• Ensure all tubing and fittings are secure and free of leaks.
• Do not install using rigid piping. System intended for use with plastic water lines (such
as PEX tubing, PE tubing, PP tubing).
• Do not install this system if any of the quick connect collets are missing from the filter
head or Y-Quick Connector. Contact an authorized InSinkErator Service agent if collets
are missing from any fittings.
• For systems using two handle HC model faucets, operate only one handle at a time.
• Important: Do not allow the unit to continuously boil.
• Regularly inspect the system. If there are signs of water leakage, turn off the water
supply and contact an authorized InSinkErator Service agent.
• A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should
be used in those applications where any leakage could cause property damage.
• For questions or concerns, please contact an authorized InSinkErator Service agent
(see back page for contact information).
Additional Consideration when Utilizing Filtration System:
• The disposable filter cartridge MUST be replaced every 6 months, at the rated capacity
or sooner if a noticeable reduction in flow rate occurs.
• Failure to replace the disposable filter cartridge at recommended intervals may lead to
reduced filter performance and cracks in the filter housing, causing water leakage or
flooding.
• Protect from freezing, remove filter cartridge when temperatures are expected to drop
below 40° F (4.4° C).
• Do not install systems in areas where ambient temperatures may go above
100°F (37.8°C).
• Do not install in direct sunlight or outdoors.

WARRANTY INFORMATION

C1300-SS/ H1300-1,-2
1-year warranty
This limited warranty is provided by InSinkErator, a business unit of Emerson Electric Co., ("InSinkErator" or
"Manufacturer" or "we" or "our" or "us") to the original owner of the InSinkErator product with which this warranty is
provided (the "InSinkErator Product"), and any subsequent owner of the location in which the Product was originally
installed ("Customer" or "you" or "your").
InSinkErator warrants to Customer that your InSinkErator Product will be free from defects in materials and workmanship,
subject to the exclusions described below, for the "Warranty Period", commencing on the later of: (a) the date your
InSinkErator Product is originally installed, (b) the date of purchase, or (c) the date of manufacture as identified by your
InSinkErator Product serial number. You will be required to show written documentation supporting (a) or (b). If you are
unable to provide documentation supporting either (a) or (b), the Warranty Period commencement date will be determined
by Manufacturer, in its sole and absolute discretion, based upon your InSinkErator Product serial number.
What is Covered
This limited warranty covers defects in materials or workmanship, subject to the exclusions below, in InSinkErator Products
used by a Customer, and includes all replacement parts and labor costs. YOUR SOLE AND EXCLUSIVE REMEDY UNDER
THIS LIMITED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE INSINKERATOR PRODUCT.
What is not Covered
This limited warranty does not extend to and expressly excludes:
• Losses or damages or the inability to operate your InSinkErator Product resulting from conditions beyond the
Manufacturer's control including, without limitation, accident, alteration, misuse, abuse, neglect, negligence
(other than Manufacturer's), failure to install, maintain, assemble, or mount the InSinkErator Product in accordance
with Manufacturer's instructions or local electrical and plumbing codes.
• Wear and tear expected to occur during the normal course of use, including without limitation, cosmetic rust,
scratches, dents or comparable and reasonably expected losses or damages.
No Other Express Warranty Applies
This limited warranty is the sole and exclusive warranty provided to the Customer identified above. No other express
warranty, written or verbal, applies. No employee, agent, dealer, or other person is authorized to alter this limited warranty or
make any other warranty on behalf of Manufacturer. The terms of this warranty shall not be modified by the Manufacturer, the
original owner, or their respective successors or assigns.
What we will do to Correct Problems
If your InSinkErator Product does not operate in accordance with the documentation provided to you, or you have questions
concerning your InSinkErator Product or how to determine when service is needed, please see attached Service Agency List.
The following information must be provided as part of your warranty claim: your name, address, phone number, your
InSinkErator Product model and serial number, and if necessary, upon request, written confirmation of either: (a) the date
shown on your installation receipt, or (b) the date shown on your purchase receipt.
Manufacturer or its authorized service representative will determine, in its sole and absolute discretion, if your InSinkErator
Product is covered under this warranty. You will be given the contact information for your closest authorized InSinkErator
Service Center. Please contact your InSinkErator Service Center directly to receive warranty repair or replacement service.
Only an authorized InSinkErator service representative may provide warranty service. InSinkErator is not responsible for
warranty claims arising from work performed on your InSinkErator Product by anyone other than an authorized InSinkErator
service representative.
If a covered claim is made during the Warranty Period, Manufacturer will, through its authorized service representative, either
repair or replace your InSinkErator Product. Cost of replacement parts or a new InSinkErator Product, and cost of labor for
repair or installation of the replacement InSinkErator Product are provided at no cost to you. Repair or replacement shall be
determined by Manufacturer or its authorized service representative in their sole discretion. If Manufacturer determines that
your InSinkErator Product must be replaced rather than repaired, the warranty on the replacement InSinkErator Product will
be limited to the unexpired term remaining in the original Warranty Period.
Limitation of Liability
TO THE EXTENT PERMITTED BY LAW, IN NO EVENT SHALL MANUFACTURER OR ITS AUTHORIZED SERVICE
REPRESENTATIVES BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING
ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE
INSINKERATOR PRODUCT OR THE MANUFACTURER'S OR ITS AUTHORIZED SERVICE REPRESENTATIVE'S NEGLIGENCE.
MANUFACTURER SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT,
REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT,
NEGLIGENCE, STRICT LIABILITY, OTHER SORT OR OTHERWISE), SHALL MANUFACTURER'S LIABILITY TO YOU EXCEED
THE PRICE PAID BY THE ORIGINAL OWNER FOR THE INSINKERATOR PRODUCT.
The term "consequential damages" shall include, but not be limited to, loss of anticipated profits, business interruption, loss
of use or revenue, cost of capital or loss or damage to property or equipment.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
WHAT TO DO
Water and steam
• Unit is boiling.
• Depress tap lever to release some water from the tank.
spits forcefully from
• Adjust water temperature using dial on tank front.
May be normal during initial set-up.
spout without turning
on the tap.
Remember that at higher altitudes, water boils at
lower temperatures.
Water is not hot.
• The unit may not be plugged in.
• Make sure the unit is connected to a properly earthed
(grounded) electric outlet.
• The electric outlet is inoperative.
• Make sure the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
LED green light on
• The unit may not be plugged in.
• Make sure that the circuit breaker or fuses are
front of tank does
functioning properly.
not illuminate.
• The electric outlet is inoperative.
• Check that the outlet is not switched off.
(H1300 model only)
Water is too hot
• Thermostat is not adjusted to
• Adjust the thermostat slowly, then depress or twist tap
or not hot enough.
your needs.
handle for 20 seconds to bring in fresh water to be heated
at the new setting. Allow 5-7 minutes for water to reach
new temperature.
Water comes out of vent
• Outlet tube is blocked.
• Check that outlet tube is not kinked, twisted or pinched.
instead of spout
• Unscrew spout end piece and clean out any debris.
Water is dripping
• The expansion chamber is not
• Unplug the unit. If the dripping does not stop after a few
from the spout/vent
draining properly due to low
minutes, check the supply valve to ensure it is fully open
intermittently.
water pressure.
and there are no obstructions in the water line reducing
the pressure below 25 psi (172 kPa; 1.7 bar). i.e., a poorly
• The spout is blocked.
mounted saddle valve, a clogged water filter, or a partially
opened shut-off valve.
• Unscrew spout end piece and clean out any debris.
Water is dripping
• Debris in the water line may be
• Unscrew spout end piece and clean out any debris.
from the spout/vent
in the tap valve seat causing a
• Depress or twist lever 7-10 times to flush tap & lines.
constantly.
slow water leak.
Divided stream.
• Debris in the end piece.
• Unscrew spout end piece and clean out any debris.
Water discoloration/
• Corrosion of unit.
• Unplug and drain as described in the Seasonal Storage/
rusty appearance.
Drainage Section on page 5 of this manual. If the water
discoloration remains after draining and refilling unit,
discontinue use and contact an authorized InSinkErator
service agent.
FILTRATION ISSUES
Water taste or odor.
• Filter water flow direction is wrong.
• Review filter tube connection instructions.
• Filter needs to be flushed out.
• Depress or twist the tap and run until the water is cold.
• Life of filter has expired.
• If there is no change, replace filter cartridge.
New filter does not fit.
• Head and bracket not fully rotated.
• Take out the new filter, put in old filter.
• Filter O-ring breach.
• Remove, inspect, reinstall filter cartridge.
The filter leaks.
• Head and bracket not fully rotated.
• Test unit by reinstalling old filter and rotating to full stop.
• Filter O-ring breach.
Check for leaks.
No water flow or low
• Life of filter has expired.
• Replace filter cartridge. See page 5.
water flow.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1300-2H1300-1

Table of Contents