1.2

SELECTION DATA

1.2.1 Specifications

(1) Ceiling recessed compact type (FDTC)

(a) Twin type
Model FDTCVA402HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit)
Item
Nominal cooling capacity
(1)
Nominal heating capacity
(1)
Power source
Cooling power consumption
Running current (Cooling)
Power factor (Cooling)
Heating power consumption
Running current (Heating)
Power factor (Heating)
Inrush current (L.R.A)
Noise level
35
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow
Outside air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.
(4) Values in [ ~ ] show the minimum to maximum range.
(5) Indoor unit specifications show the specifications for one unit. Capacity and running characteristics values are shown for the case where two indoor units
are combined and run together.
Model
kW
kW
kW
A
%
kW
A
%
A
Powerful mode Hi:46 Me:42 Lo:38
dB(A)
52
mm
kg
kg
r
W
Powerful mode Hi:13.5 Me:11.5 Lo:10
CMM
W
Wired remote control switch (Optional : RC-E1R)
Wireless kit (Optional:RCND-KIT-HER)
Liquid line
mm
Gas line
(in)
Connectable with VP25 (I.D.25mm, O.D.32mm)
Item
Indoor air temperature
DB
27˚C
20˚C
FDTCVA402HESP2R
FDTCA201R
3 Phase, 380-415V 50Hz/380V 60Hz
Mild mode Hi:42 Me:38 Lo:35
Unit 248 × 570 × 570
Panel 35 × 700 × 700
19.5 (Unit:16 Panel:3.5)
Louver fin & inner grooved tubing
Microcomputer controlled de-icer
Turbo fan × 1
50 × 1
Direct line start
Mild mode Hi:11.5 Me:10 Lo:8
Available
Long life filter ×1(washable)
Rubber sleeve (for fan motor)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat.
Indoor branch pipe, Outdoor main pipe: φ9.52 (3/8")
Indoor branch pipe: φ12.7 (1/2"), Outdoor main pipe: φ15.88 (5/8")
Necessary (both Liquid & Gas lines)
Mounting kit. Drain hose
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
3
-
-
FDCVA402HESAR
10.0 [6.1~11.2]
11.2 [5.6~12.5]
2.84/2.84
4.2/4.4
98/98
3.08/3.08
4.5/4.8
99/97
5
50
845 × 970 × 370
74
RM-B5125MDE31
Direct line start
Straight fin & inner grooved tubing
Electronic expansion valve
R410A
3.8 [Pre-charged up to the piping length of 30m]
0.7 (M-MA68)
Propeller fan × 1
120 × 1
Direct line start
Cooling: 75, Heating: 73
Rubber mount (for compressor)
20 (Crank case heater)
– (Indoor unit side)
Internal thermostat for fan motor.
Anomalous discharge temperature protection.
Flare piping
Decorative Panel
WB
24˚C
6˚C
Standards
ISO-T1