This furnace is equipped with a multi-speed circulator blower. This
blower provides ease in adjusting blower speeds. The Specification
Sheet applicable to your model provides an airflow table, showing
the relationship between airflow (CFM) and external static pressure
(E.S.P.), for the proper selection of heating and cooling speeds. The
heating blower speed is shipped set at "B", and the cooling blower
speed is set at "D". These blower speeds should be adjusted by the
installer to match the installation requirements so as to provide the
correct heating temperature rise and correct cooling CFM.
Use the dual 7-segment LED display adjacent to the dipswitches to
obtain the approximate airflow quantity. The airflow quantity is
displayed as a number on the display, rounded to the nearest 100
CFM. The display alternates airflow delivery indication and the op-
erating mode indication.
Example: The airflow being delivered is 1225 CFM. The display
Example:
Example:
Example:
Example:
indicates 12. If the airflow being delivered is 1275, the display
indicates 13.
1. Determine the tonnage of the cooling system installed with
the furnace. If the cooling capacity is in BTU/hr divide it by
12,000 to convert capacity to TONs.
Example:
Example:
Example:
Example: Cooling Capacity of 30,000 BTU/hr.
Example:
30,000/12,000 = 2.5 Tons
2. Determine the proper air flow for the cooling system. Most
cooling systems are designed to work with air flows between
350 and 450 CFM per ton. Most manufacturers recommend
an air flow of about 400 CFM per ton.
Example:
Example:
Example:
Example:
Example: 2.5 tons X 400 CFM per ton = 1000 CFM
The cooling system manufacturer's instructions must be checked
for required air flow. Any electronic air cleaners or other devices
SUPPLY
AIR
T
SUPPLY
T
T
RISE =
-
SUPPLY
RETURN
T
RETURN
RETURN
AIR
WARNING
 
 
 
 
 
OR
DEATH
DUE
TO
ELECTRICAL
SHOCK
 
 
 
BEFORE
CHANGING
SPEED
S S S S S
- - - - -
T T T T T A R
A R
A R
A RT T T T T
A R
U P
U P
U P
U P
U P
may require specific air flows, consult installation instructions of
those devices for requirements.
3. Knowing the furnace model, locate the high stage cooling
air flow charts in the Specification Sheet applicable to your
model. Look up the cooling air flow determined in step 2
and find the required cooling speed and adjustment setting.
Example:
Example:
Example:
Example:
Example:
4. Continuous fan speed is 30% of the furnace's maximum
airflow capability.
Example:
Example:
Example:
Example:
Example:
5. Locate the blower speed selection DIP switches on the
integrated control module. Select the desired "cooling"
speed tap by positioning switches 1 and 2 appropriately.
Select the desired "adjust" tap by positioning switches 3 and
4 appropriately. Refer to the following figure for switch
 
.
TAPS
positions and their corresponding taps. Verify CFM by noting
the number displayed on the dual 7-segment LED display.
6. The multi-speed circulator blower also offers several custom
ON/OFF ramping profiles. These profiles may be used to
enhance cooling performance and increase comfort level.
The ramping profiles are selected using DIP switches 5 and
6. Refer to the following figure for switch positions and
their corresponding taps. Refer to the bullet points below
for a description of each ramping profile. Verify CFM by
noting the number displayed on the dual 7-segment LED
display.
Profile A provides only an OFF delay of one (1) minute at
Profile A
Profile A
Profile A
Profile A
100% of the cooling demand airflow.
OFF
Profile B
Profile B
Profile B
Profile B
Profile B ramps up to full cooling demand airflow by first
stepping up to 50% of the full demand for 30 seconds. The
25
P P P P P
R R R R R O C E D U R E
O C E D U R E
O C E D U R E
O C E D U R E
O C E D U R E A N D
A N D
A N D
A N D
A N D
A *MVC80704BX furnace installed with a 2.5
ton air conditioning system. The air flow
needed is 1000 CFM. Looking at the cooling
speed chart for *MVC80704BX, find the air flow
closest to 1000 CFM. A cooling airflow of 990
CFM can be attained by setting the cooling
speed to "C" and the adjustment to "-" (minus).
If the furnace's maximum airflow capability is
2000 CFM, the continuous fan speed will be
0.30 x 2000 CFM = 600 CFM.
Switch Bank: S4
DIP Switch No.
Ramping
Profiles
5
A*
OFF
B
ON
C
OFF
D
ON
(*Indic ates factory setting)
100% CFM
A A A A A
D J US T M E N T
D J U
D J U
D J U
D J U
S T M E N T
S T M E N T
S T M E N T
S T M E N T
6
OFF
OFF
ON
ON
100% CFM
OFF
1 min

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents