4-way Air Discharge Cassette Type
How to set up 8°C
Operation
types only)
Preheating operation can be set for cold regions
where room temperature drops to below zero.
Procedure
Push simultaneously
seconds or more when the air conditioner is not
working.
After a while, the display part flashes as shown
below. Check the Displayed CODE No. is [10].
• When the CODE No. is other than [10], push
button to erase the display and repeat
procedure from the first step.
(After pushing
remote controller is not accepted for approx. 1
minute.)
Procedure
Every pushing
in the group control is displayed in order. Select
the indoor unit of which setup is changed. In this
time, the position of the indoor unit of which setup
is changed can be confirmed because fan and
louver of the selected indoor unit operate.
Procedure
Using temp. setup
CODE No. [d1].
Procedure
Using timer time
DATA [0001].
Setup data
Procedure
Push
In this time, the setup finishes when the display
changes from flashing to lighting.
Procedure
Push
When pushing
and the status
31-EN
(SM110 and SM140
1
+
+
button, operation of the
(* Display changes according to
the model No. of indoor unit.)
2
button, the indoor unit No.
3
/
buttons, specify
4
/
buttons, select SET
8°C Operation setting
None
0000
(Factory Shipping)
0001
8°C Operation setting
5
button.
6
button.(Setup is determined.)
button, the display disappears
Becomes the usual stop status. (When pushing
button the operation from the remote
controller is not accepted for approx. 1 minute.)
• This function is available only when connected
to the new SDI series 4 (RAV-SP**4AT-E).
buttons for 4
– 31 –