Set-Up Adjustments; Beam Landing - Sony KV-34FQ75A Service Manual

Fd trinitron
Table of Contents

Advertisement

When complete readjustment is necessary or a new picture tube is
installed, carry out the following adjustments.
Unless there are specific instructions to the contrary, carry out
these adjustments with the rated power supply.
Unless there are specific instructions to the contrary, set the
controls and switches to the following settings :
Contrast
.................................. normal
Brightness .................................. normal

3-1. Beam Landing

Preparation :
1.
In order to reduce the influence of geomagnetism on the set's
picture tube, face it in an easterly or westerly direction.
2.
Switch on the TV set's power and degauss with a degausser.
(1) Adjustment of Correction Magnet for Y-Splitting Axis.
1.
Input a crosshatch signal from the pattern generator.
2.
Set the Picture control to minimum and confirm that the
Brightness control is set to normal.
3.
Position the neck assembly as indicated in Fig.3-3.
4.
Loosen the deflection yoke fixing screw.
5.
Move the deflection yoke as far forward as is possible.
6.
Adjust the upper and lower pin symmetrically by opening or
closing the Y-splitting axis correction magnets located on the neck
assembly. [See Fig 3-1 and Fig 3-2]
7.
Return the deflection yoke to its original position and re-tighten its
fixing screw.
Fig.3-1
Y-splitting axis correction magnet
Fig.3-2
SECTION 3

SET-UP ADJUSTMENTS

Carry out the adjustments in the following order :
3-1.
3-2.
3-3.
3-4.
Note : Test equipment required.
Caution :
High voltages are present on the Deflection yoke terminals - take care
when handling the Deflection yoke whilst carrying out adjustments.
(2) Landing
Note : Before carrying out the following adjustments adjust the
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Switch the pattern generator to green then blue and confirm the
11. If the beam does not land correctly in all the corners of the screen,
Fig.3-3
20
Beam Landing.
Convergence.
Focus.
White Balance.
1.
Color bar/pattern generator.
2.
Degausser.
3.
Oscilloscope.
4.
Digital multimeter.
magnets as indicated below [See Fig.3-4].
Input a crosshatch signal from the signal generator.
Rough-adjust the focus and horizontal convergence.
Switch from the crosshatch pattern to an all-red pattern.
Move the deflection yoke backwards and adjust with the purity
magnet so that the red is at the centre and it aligns
symmetrically [See Fig.3-5].
Move the deflection yoke forward to the point where the entire
screen just becomes red [Mark its position].
Move the deflection yoke further forward until the screen just
changes colour at the edges. [Mark its position]
Position the deflection yoke between the two marks indicated
above.
Input a crosshatch pattern from the pattern generator and rotate the
deflection yoke so that the horizontal lines are parallel with the top
and bottom of the screen.
When the position of the deflection yoke has been determined,
fasten it with its fixing screw.
purity.
use disk magnets to correct it. [Confirm the corner landing for
green and blue]
Neck assy
G2
G1
+
G3
Align the edge
of the neck assy with
the edge of the G2 grid
on the G3 side.