Test Mode For Base Unit
Press the "  " and "#" keys at the same time about 2 seconds while turning the power on, the confirmation beep
will sound to indicate that the unit is in the test mode.
1. To change the TEST mode: Press the number key for the corresponding TEST mode.
2. To change channel:
3. To cancel Test mode:
STEP
FUNCTION
1
VO/TX FRQ. ADJ
2
TX MODE CHECK
3
TX DATA
4
RX SENS.
5
SQ SENS.
6
RING CHECK
7
DUAL TONE CHECK
8
DATA IN CHECK
9
CHANNEL DATA CHECK
10
DUPLEX
11
INT COM
*1 : "0000..." (250Hz) will be fed out continuously as transmitting data.
*2 : Bell rings and INTCOM LED lights when sensing SQ.
-6#= (YHU\#SXVKLQJ#RI#)/$6+#NH\#PDNHV#WRQH#FKDQJH1#+,Q#WKH#FDVH#RI#'XDO#7RQH/#FKDQJHV#DV
4Ö5Ö6Ö7Ö8Ö9Ö:Ö;Ö<Ö3Ö∗Ö&Ö41,
DTMF Frequency
ROW1 :
ROW3 :
COL1
:
COL3
:
*4 : Bell rings when the received data are "0000..." (250Hz).
*5 : Charge LED lights when detecting Charge ON.
Channel rotation
4<#Ö53Ö54Ö73Ö4Ö5Ö6Ö7Ö81111111111116:Ö6;Ö6<Ö73

ALIGNMENT PROCEDURE

(Refer to the following table)
Press the "RDL" key, but if changing the step, the channel returns to the start
channel.
Bell rings (except for Step 6), charge the Handset (except for Step 9) or Power
off.
KEY
START CH
1
19
2
19
3
19
4
19
5
19
6
19
7
19
8
19
9
19
0
19
MEM
19
697
ROW2 :
852
ROW4 :
1209
COL2
:
1477
TX CONT
TX MUTE
L
L
L
H
L
L
H
L
L
L
H
L
H
L
L
L
H
L
L
H
L
H
770
941
1336
3
RX MUTE
RL CONT REMARKS
L
L
L
H
L
L
H
H
H/L
H
L
L
L
H
L
H
L
L
H
H
H
L
*1
*2
*3
*4