Danby DER201W Owner's Use And Care Manual page 21

Hide thumbs Also See for DER201W:
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL CONNECTIONS (CONT'D)
(3) POWER CORD AND STRAIN RELIEF INSTALLATION
(A) Remove the wire cover (on the lower back of the range) by
removing its top center screw. Do not discard this screw.
(B) Remove the knockout ring (1 ⅜ ≤) located on the bracket
directly below the terminal block. To remove the knockout,
use a pair of pliers to bend the knockout ring away from the
bracket and twist until the ring is removed.
(C) For power cord installations only (see the next step
D if using a conduit), assemble the strain relief in the hole.
Insert the power cord through the strain relief and tighten.
Allow enough slack to easily attach the cord terminals to the
terminal block. If tabs are present at the end of the winged
strain relief, they can be removed for better fi t.
NOTE: Do not install the power cord without a strain
relief. The strain relief bracket should be installed before
reinstalling the rear range wiring cover.
Skip to Step 4 or 5.
(D) For conduit installations only, purchase a squeeze
connector matching the diameter of your conduit and
assemble it in the hole. Insert the conduit through the
squeeze connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze
connector. The squeeze connector should be installed
before reinstalling the rear range wiring cover.
Skip to Step 6 or 7.
INSTALLATION INSTRUCTIONS
Knockout ring
in bracket
Strain relief
Power cord
Squeeze
connector
Conduit
19
Terminal block
(appearance may vary)
Knockout ring
removed
Terminal
block
Bracket
Terminal
block
Bracket

Advertisement

Table of Contents
loading

Table of Contents