Item
Function
VF1
Turn the zebra indication on the
viewfinder connected to the VF1
connector on/off.
VF2
Turn the zebra indication on the
viewfinder connected to the VF2
connector on/off.
MONITOR
Turn the zebra indication on the monitors
connected to the MONITOR OUT
connectors on/off.
VBS
Turn the zebra indication on a device
connected via the REMOTE connector
on/off.
ZEBRA TYPE
Select the zebra(s) to be displayed:
1, 2, or 1&2
ZEBRA1 LEVEL Adjust the level (50 to 109%) of the zebra
1 indication (factory setting: 70%).
WIDTH
Adjust the width (0 to 30%) of the zebra 1
indication (factory setting: 10%).
ZEBRA2
Adjust the level (50 to 109%) of the zebra
2 indication (factory setting: 100%).

3-6-7 Setting the Cursor Indication

You can display a cursor on the viewfinder and monitor
screen.
Example: Box cursor
Setting the cursor indication is performed on the
<CURSOR> page of the USER (OPERATION) menu.
<CURSOR> page
< C U R S O R >
V F 1
V F 2
M O N I T O R
B O X / C R O S S
H P O S I T I O N
V P O S I T I O N
W I D T H
H E I G H T
Menu item
Function
VF1
Turn the cursor indication on the viewfinder
connected to the VF1 connector on/off.
VF2
Turn the cursor indication on the viewfinder
connected to the VF2 connector on/off.
U 0 7
B
:
O F F
: O F F
: O F F
:
B O X
:
0
:
0
:
9 6 0
:
5 4 0
Menu item
Function
MONITOR
Turn the cursor indication on the monitors
connected to the MONITOR OUT
connectors on/off.
BOX/CROSS
Select the type of the cursor to be displayed.
H POSITION
Adjust the horizontal position of the center
(–960 to 960).
V POSITION
Adjust the vertical position of the center
(–540 to 540).
WIDTH
Adjust the width (from the center to right or
left side) of the cursor (16 to 1920).
HEIGHT
Adjust the height (from the center to top or
bottom) of the cursor (16 to 1080).

3-6-8 Checking the Power Voltage

The settings of the NEAR END and END values to warn
of low voltage of a power supply can be checked on the
<BATTERY ALARM> page of the USER (OPERATION)
menu.
<BATTERY ALARM> page
< B A T T E R Y A L A R M >
D C I N ( 2 4 V )
B
T Y P E :
A C A D P
N E A R E N D
: ( 2 2 . 2 )
E N D
: ( 2 1 . 6 )
D C I N ( 1 2 V )
T Y P E : A C A D P
N E A R E N D
: ( 1 1 . 1 )
E N D
: ( 1 0 . 8 )
Menu item
Indication
DC IN (24V)
Voltage of the 24-V power
TYPE
Select the type of the 24-V power source.
NEAR END
NEAR END value specified for the 24-V
power source of the selected type
END
END value specified for the 24-V power
source of the selected type
DC IN (12V)
Voltage of the 12-V power
TYPE
Select the type of the 12-V power source.
NEAR END
NEAR END value specified for the 12-V
power source of the selected type
END
END value specified for the 12-V power
source of the selected type
This page is intended for display only. You can only switch
the type. If you want to change the values, use the <BATT
ALARM SET> page of the MAINTENANCE menu.
Viewing and Setting the Viewfinder Displays
U 1 6
2 4 . 2 V
1 2 . 8 V