Users Guide and
HE
Range
A
Important Warranty Information
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2014

Advertisement

Table of Contents
loading

Summary of Contents for Baxi Main 12 HE A

  • Page 1 Users Guide and Range Important Warranty Information Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2014...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2014 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Operating The Boiler

    2. The fan will start to run and after a short period the ignition spark will commence. Sparking will continue until the flame is established then stop automatically. Check that a flame is visible through the sight glass. © Baxi Heating UK Ltd 2014...
  • Page 4: Troubleshooting

    If no gas, consult your supplier. Sight Glass Boiler operating satisfactorily. CONTACT YOUR Boiler fails to light ? INSTALLER OR SERVICE ENGINEER. Press the Reset Button If boiler will not light. Reset Button © Baxi Heating UK Ltd 2014...
  • Page 5 If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible © Baxi Heating UK Ltd 2014...
  • Page 6: Clearances

    11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this For Servicing Purposes would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 280mm In Operation Fig. 2 © Baxi Heating UK Ltd 2014...
  • Page 7: Care Of The Boiler

    1. The boiler does not have integral frost protection. It is recommended that the installer fits a suitable protection device to the system controls if required. For frost protection the boiler must not be switched off at the isolation switch on the wall. © Baxi Heating UK Ltd 2014...
  • Page 8: Legislation

    The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The completed Benchmark Checklist may be required in the event of any warranty work. © Baxi Heating UK Ltd 2014...
  • Page 9: Notes

    6.0 Notes © Baxi Heating UK Ltd 2014...
  • Page 10: Notes

    6.0 Notes © Baxi Heating UK Ltd 2014...
  • Page 11: Emergency

    Telephone the National Gas Emergency Service on:- 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. © Baxi Heating UK Ltd 2014...
  • Page 12: Warranty & Service

    This service must be completed by • your GAS SAFE registered installer; or • heateam - the service division of Baxi (telephone 0844 871 1545); or • another GAS SAFE registered engineer If you experience a problem with your boiler Please check that there is a gas, electricity and water supply to the boiler.