Sony MZ-E710 Service Manual page 17

Hide thumbs Also See for MZ-E710:
Table of Contents

Advertisement

. Overall MO adjustment items
2
Item No.
112
ALFA offset adjustment
113
IJ offset adjustment
114
FE offset adjustment
118
AW DW OFFSET
224
TE offset adjustment
221
TE gain adjustment
224
TE offset adjustment
236
ABCD gain adjustment
237
KF gain adjustment
238
RF gain adjustment
244
Focus gain adjustment
245
Tracking gain adjustment
120
Focus servo ON
122
TE offset adjustment (TON)
121
TE gain adjustment
122
TE offset adjustment (TON)
123
TE offset adjustment (TEIN)
124
TE offset adjustment (TWPP)
130
Tracking servo ON
131
TE offset adjustment (TWPP/RF)
136
ABCD gain adjustment
137
KF gain adjustment
144
FCS gain adjustment
145
Tracking gain adjustment
139
BPF fo adjustment
134
TWPP gain adjustment
131
TE offset adjustment (TWPP/RF)
132
TE offset adjustment (TWPP/DSP)
35
GOD offset correction.
5-8. REWEITING BATCH DATA AFTER REPLACING
THE NONVOLATILE MEMORY
Rewrite the program correction data after replacing the nonvolatile
memory.
5-8-1 Method for rewriting the corrected data
(when using Version 1.000)
1. Set in Test mode.
2. Set in Manual mode and enter the item number 022.
LCD display
022 PatClr CC
3. Press the
key to reset the batch data.
(Writing is complete if the setting changes to DD.)
LCD display
022 PatClr DD
4. Press the
key and enter the item number 023.
>
LCD display
023 Patch 00
Contents
Data.
5. Press the
key and set the adjustment setting to 01.
VOL +
LCD display
023 Patch 01
6. Press the
key.
LCD display
022 PatClr CC
This section (address) flashes.
7. Press the
key.
x
(The data section flashes.)
8. Press the
and
VOL +
VOL –
data while referring to the batch data list.
9. Press the
key and the address section flashes.
10. Press the
keys and set the address value in the next
VOL +
address for adjustment.
LCD display
023 8922
This section (address) flashes.
11. Press the
key.
x
LCD display
023 8922
12. While referring to the batch data table repeat the data correction
write procedure from steps 8 through 11 until the address 899E
is set.
13. Press the
key.
(The address value flashes.)
14. Press the
key to quit the batch data write mode.
LCD display
023 Patch 01
15. Press the
key.
LCD display
LCD display
023 Patch CC
LCD display
023 Patch DD
16. Turn off the power.
MZ-E710
Data.
keys and set the adjustment
00
00
This section (data) flashes.
After finished writing data.
17

Hide quick links:

Advertisement

Table of Contents
loading