Installation; Temperature And Pressure Relief Valve - InSinkErator W-152 Installation, Care And Use

Table of Contents

Advertisement

installation

REQUIRED ABILITY
INSTALLATION OR SERVICE OF THIS WATER HEATER
REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED
TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND
ELECTRICAL WORK ARE INVOLVED.
The installation must conform to these instructions, the local code
authority having jurisdiction, and the requirements of the power
company. In the absence of code requirements follow NFPA-70, The
National Electrical Code, which may be ordered from: American
Standards Institute, 1430 Broadway, New York, NY 10018.
"INSULATION BLANKETS" ARE AVAILABLE FOR EXTERNAL USE
ON ELECTRIC WATER HEATERS. BUT ARE NOT
RECOMMENDED BY IN-SINK-ERATOR.
IF YOU CHOOSE TO IGNORE OUR RECOMMENDATION AND
INSTALL AN INSULATION BLANKET ON THIS HEATER YOU
MUST ADHERE TO THE FOLLOWING PRECAUTIONS IN ORDER
TO PREVENT SERIOUS INJURY OR DEATH TO YOURSELF OR
OTHERS.
1. THE JUNCTION BOX, EXTERNAL WIRING, THERMOSTATS
OR HEATING ELEMENTS ON ELECTRIC WATER HEATERS
MUST NOT BE COVERED.
2. THE TEMPERATURE-PRESSURE RELIEF VALVE MUST NOT
BE COVERED.
3 OPERATING INSTRUCTIONS, INSTALLATION OR SAFETY
RELATED LABELS MUST NOT BE COVERED.
4 THE AMERICAN NATIONAL STANDARDS & FEDERAL LAWS
PERTAINING TO WATER HEATERS REQUIRE THAT
INSTRUCTIONS & SAFETY LABELS REMAIN ON THE WATER
HEATER PROPER. DO NOT REMOVE INSTRUCTIONS OR
SAFETY LABELS FROM THE HEATER.
5. IN-SINK-ERATOR WILL NOT BE LIABLE FOR ANY INCIDENT
RESULTING FROM THE USE OF INSULATION BLANKETS.
6. WATER AND/OR CONDENSATE CAN COLLECT IN AN
INSULATION BLANKET. IN-SINK-ERATOR WILL NOT BE
LIABLE FOR ANY RUST OR CORROSION DAMAGE CAUSED
BY THE INSTALLATION OF INSULATION BLANKETS.
TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE
TO YOUR SAFETY. PLEASE READ THOROUGHLY BEFORE USING APPLIANCE.
GENERAL
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN
RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into a three pin receptacle that is
properly installed and grounded in accordance with all local
codes and ordinances.
Have a licensed electrician check for ground continuity of the
electrical supply system to insure proper grounding of the
water heater.

TEMPERATURE AND PRESSURE RELIEF VALVE

To reduce the risk of excessive pressures and temperatures in this
water heater install temperature and pressure protective equipment
required by local codes but not less than a combination temperature
and pressure relief valve certified by a nationally recognized testing
laboratory that maintains periodic inspection of production of listed
equipment or materials, as meeting the requirements for Relief
Valves and Automatic Gas Shutoff Devices for Hot Water Supply
Systems, ANSI Z21.22. This valve must be marked with a maximum
set pressure not to exceed the marked maximum working pressure
of the water heater. Install the valve into an opening provided and
marked for this purpose in the water heater, and orient it or provide
tubing so that any discharge from the valve will exit only within 6
inches above or at any distance below the structural floor and
cannot contact any live electrical part. The discharge opening must
not be blocked or reduced in size under any circumstances.
Check the metal tag on the relief valve and compare it to the
3