HOW YOUR WATER SOFTENER
WORKS
TANK
LIGHT
To light
the inside
of the salt storage
tank,
press
the
TANK
LIGHT
button
on the faceplate.
Press
the
same button
again
to turn
the light off, or it will turn
off automatically
in 4 minutes.
_I r-II-I Pu
tank light ON
indicator
WATER
FLOW THROUGH
THE SOFTENER
To view
the gallon
(or liter) per minute
water
flow
rate through
the softener,
if not already
displayed,
press
the SELECT
2 button.
If soft
water
is being
used,
the flow rate to the closest
1/10
gallon
(or li-
ters)
shows.
If all faucets
and
water
using
ap-
pliances
are off, the display
will show
0 flow.
_,+m_+ _
--t,flH--I I
I
FLOWRAr_
I
AVERAGE
DAILY
GALLONS
or LITERS
Press
the SELECT
2 button
again
to show
the aver-
age number
of gallons
of soft water
the household
uses
each
day. This water
usage
figure
is adjusted
daily by the faceplate
timer.
To turn this display
off,
press
the SELECT
2 button
once more.
?,l
,nn +.I
++1
;
r-,q
I--+-.I+°
RECHARGE
TIME
REMAINING
and VALVE
POSITION
INDICATORS
One of the valve position
indicators
(Serv, Fill, Brine,
Bkwsh,
Rinse)
is displayed
while
the softener
is re-
charging
(See *Note on page 2- 1 if the CLEAN
fea-
ture is ON). RECHARGE
flashes
in the display
and,
beginning
with
Brine,
the minutes
of recharge
re-
maining
before
return
to service
appears
in place of
the present
time.
When
the valve
is moving
from
one cycle
to another,
both
position
indicators
are
flashing.
valve
recharge
position
time
indicators
remainin_
....
I I...I 0 ""
PROGRAM
MEMORY
If electrical
power
to the softener
goes off, the time
display
is blank
but the face plate
timer
keeps
the
correct
time
for about
48 hours.
When
electrical
power
comes
on again,
you have to reset the present
time
only
if the display
is flashing.
The HARD-
NESS
and RECHARGE
TIME
never
require
reset-
ting unless
a change
is desired.
Even
if the timer is
incorrect
after
a long
power
outage,
the softener
works
as it should
to keep your water
soft. Howev-
er, regenerations
may
occur
at the
wrong
time
of
day until
you reset
the timer
to the correct
time of
day.
ERROR
CODE
An error
code could appear
in the face plate
display
if a problem
occurs
in the softener
electronics.
If you
see an error
code instead
of the present
time of day,
look at Troubleshooting
page
5-2
and/or
call the
Kenmore
Water
Line 1- 800- 426- 9645.