2

SPECIFICATIONS

2-1. FLOOR STANDING TYPE
Indoor unit
Model name
Outdoor unit
Capacity
Cooling
Total input
EER
Energy label class
SHF
Capacity
Heating
Total input
COP
Energy label class
Booster heater
Phase
Power supply
Cycle
Voltage
Breaker size
Air flow at cooling
Indoor unit
(Low-Medium-High-Super High)
Air flow at heating
(Low-Medium-High-Super High)
External static pressure
Sound level at cooling
(Low-Medium-High-Super High)
Sound level at heating
(Low-Medium-High-Super High)
External finish (Panel)
Dimension
Unit (Panel)
Weight
Unit (Panel)
Air flow at cooling
Outdoor unit
(Low - High)
Air flow at heating
(Low - High)
Sound level at cooling
(Low - High)
Sound level at heating
(Low - High)
External finish
Dimension
Weight
Refrigerant pipe size
Gas side O.D.
Liquid side .
Height difference
Refrigerant pipe length
Length
NOTE:
1. Rating conditions (ISO T1)
Cooling
Indoor : D.B. 27
Heating
Indoor : D.B. 20
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Btu/h
kW
kW
Btu/h
kW
kW
kW
Hz
V
A
CMM
CFM
CMM
CFM
Pa
dB(A)
dB(A)
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
CMM
CFM
CMM
CFM
dB(A)
dB(A)
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
mm
inch
mm
inch
m
m
(80°F) W.B. 19
(66°F)
(68°F)
Indoor
KA25, KA35VA
32°C D.B. , 23°C W.B.
46°C D.B.
21°C D.B. , 15°C W.B.
-10°C D.B.
24°C D.B. , 18°C W.B.
27°C D.B.
20°C D.B.
-10°C D.B. ,-11°C W.B. -20°C D.B. ,-21°C W.B.
MFZ-KA25VA
SUZ-KA25VA(H)
8,500
2.5(0.9-3.4)
0.58
4.31
A
0.66
11,600
3.4(0.9-5.1)
0.835
4.07
A
1
50
230
10
4.8 - 5.8 - 7.1 - 8.7
170 - 205 - 250 - 310
5.0 - 6.2 - 7.6 - 9.1
180 - 220 - 270 - 320
0
22 - 27 - 32 - 37
22 - 27 - 32 - 37
White Munsell 1.0Y 9.2/0.2
34.3
1,210
32.3
1,140
46
46
Ivory Munsell 3.0Y 7.8/1.1
800
285
550
31 - 1/2
11 - 1/4
21 - 5/8
30
66
9.52
3/8
6.35
1/4
Max. 12
Max. 20
Outdoor : D.B. 35
(95°F) W.B. 24
Outdoor : D.B. 7
(45°F)
W.B. 6
3. Guaranteed voltage
Outdoor
KA50
KA25,KA35VAH
4. Above data are based on the indicated voltage.
43°C D.B.
46°C D.B.
-15°C D.B.
-10°C D.B.
3
MFZ-KA35VA
MFZ-KA50VA
SUZ-KA35VA(H)
SUZ-KA50VA
11,900
3.5(0.9-3.9)
4.8(0.9-5.4)
1.09
3.21
A
0.65
13,600
4.0(0.9-6.2)
6.0(0.9-7.9)
1.10
3.64
A
1
50
230
10
5.0 - 6.1 - 7.4 - 9.1
7.1 - 7.9 - 9.2 - 10.7
180 - 215 - 260 - 320
250 - 280 - 325 - 380
5.2 - 6.2 - 7.8 - 9.5
7.4 - 8.8 - 9.8 - 11.8
185 - 220 - 275 - 335
260 - 310 - 345 - 415
0
23 - 28 - 33 - 38
32 - 35 - 39 - 43
25 - 28 - 33 - 38
32 - 35 - 39 - 44
700
200
600
27 - 5/8
7 - 7/8
23 - 5/8
14
31
33.4
1,180
970 - 1,730
33.4
1,180
1,300 - 1,730
47
48
800
285
550
31 - 1/2
11 - 1/4
21 - 5/8
33
73
9.52
3/8
6.35
1/4
Max. 12
Max. 20
(75°F)
(43°F)
198~264V, 50Hz
Indoor unit
Single phase, 230V 50Hz
Outdoor unit
Single phase, 230V 50Hz
16,400
1.55
3.1
B
0.63
20,500
1.86
3.23
C
1
50
230
20
0
27.5 - 49
36.8 - 49
51 - 53
53 - 55
840
330
850
33 - 1/16
13
33 - 7/16
53
117
12.7
1/2
6.35
1/4
Max. 30
Max. 30

Hide quick links: