1
VSX-D509S, VSX-D509S-G,
VSX-D409, VSX-D409-G
2.2 AMP&PRIMARY (2/2) and VOLTAGE SELECT SW ASSY ASSYS
A
C
2/2F
(VSX-D509S, VSX-D509S-G/BXJI : AWX7486)
(VSX-D409, VSX-D409-G/BXJI : AWX7482)
GB
CN591
B
C
BXJI : ATT7038
• NOTE FOR FUSE REPLACEMENT
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE.
CAUTION -
REPLACE WITH SAME TYPE AND RATINGS ONLY.
D
C
S
2/2F
8
1
2
AMP&PRIMARY ASSY
CAUTION : FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE.
REPLACE ONLY WITH SAME TYPE
NO. 491.315 FOR IC52 MFD, BY
LITTELFUSE INC.
BXJI : REK1026 (T2.5A)
BXJI : REK1026 (T2.5A)
BXJI : REK1029 (T5.0A)
F
2
3
POWER TRANSFORMER
S
F
VOLTAGE SELECT SW ASSY
(BXJI TYPE : AWX7442)
LIVE
NEUTRAL
AC POWER CORD
BXJI : VDG1080
3
4
VOLTAGE SELECT
SW (AKX-507)
4