Linear Code Type Security Level - Motorola Symbol MiniScan MSXX07 Series Integration Manual

Motorola scanner user manual
Table of Contents

Advertisement

10 - 18 Symbol MiniScan MSXX07 Series Integration Guide

Linear Code Type Security Level

NOTE Does not apply to Code 128.
MiniScan scanners offer four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5).
Select higher security levels for decreasing levels of bar code quality. As security levels increase, the scanner's
aggressiveness decreases.
Select the security level appropriate for bar code quality.
Linear Security Level 1
The following code types must be successfully read twice before being decoded:
Code Type
Codabar
MSI Plessey
D 2 of 5
I 2 of 5
Linear Security Level 2
All code types must be successfully read twice before being decoded.
Length
All
4 or less
8 or less
8 or less
Linear Security Level 1
*Linear Security Level 2