5.5 LINE FILTER (2 X 25mH)
ELECTRICAL DATA
Inductance: L1-2=L3-4-30mH - 15% - +20%
Resistance: R 1-2 = R 3-4 = 1.0 ohm (max)
Rated current: Irms = 0.50 A
(F= 1 Khz V= 1 Vms)
LEAKAGE INDUCTANCE
L 1-2 = L 3-4
100+/- 20%uH