Faucet Electronics & Battery Change; Troubleshooting The System - Whirlpool WHEMB40 Installation And Operation Manual

Hide thumbs Also See for WHEMB40:
Table of Contents

Advertisement

Faucet Timer
Inside the faucet base is a battery operated 6 month timer.
An amber LED indicator is also located in the front of the faucet base. This LED will flash continuously
after 6 months have passed. This indicates that it is time to replace the battery and filters.
Battery Change
To change the battery, complete the following steps.
1. Loosen the screw on the right side of the faucet base.
2. Press the battery housing upwards from faucet base
until it releases from the base.
3. Replace the battery (CR 2032 or equivalent). Place
battery into the holder with the positive (+) side facing
the back of the holder.
NOTE: Recycle or properly dispose of the old battery.
4. When the battery is first replaced the light in the base
will flash six times and turn off. This indicates the bat-
tery is fully charged. After the six flashes the timer
enters the 6 month time cycle. If it repeatedly flashes
two times, the battery is weak and needs to be replaced.
5. Re-install the battery housing and firmly tighten the
mounting screw.

Troubleshooting the System

Problem: No water or decreased water flow.
Cause: Filter 1 is clogged.
Cause: Flow through the microbiological purifying filter will
decrease and eventually clog when exposed to an
excess of microbiological loading materials in the water.
This failsafe feature reduces the chance of product use
beyond its intended life, and will shut down the filter
when it is exposed to contaminated water.
Problem: Taste and/or Odor.
Cause: Filter cartridges exhausted.
Cause: System contaminated.
Problem: Faucet LED indicator light does not function after battery change.
Cause: Battery dead.
Cause: Battery installed incorrectly.
Problem: Water leaks at push connect fittings.
Cause: Tubing not pushed in all the way.
Cause: Tubing not cut square.
Cause: Tubing nicked.
Cause: Outer tubing surface not smooth.
Call toll free 1-866-986-3223, Monday - Friday, 8 am - 7 pm EST, or visit www.ecodynewatertreatment.com
Faucet Electronics
Need help troubleshooting?
9
battery
housing
battery,
negative (-) side
facing the front
Correction: Replace the filter 1 cartridge.
Correction: Replace all filter cartridges.
Correction: Replace all filter cartridges.
Correction: Sanitize system. Call 1-866-986-3223
for instructions.
Correction: Replace with new battery.
Correction: Install battery correctly.
Correction: Push tubing in all the way into fittings.
Correction: Cut tubing square.
Correction: Remove nicked portion, reinsert tubing
into fitting.
Correction: Remove rough portion, reinsert tubing
into fitting.
screw
FIG. 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents