INSTALLATION

The following steps are required to install the Canopy backhaul module:

Unpack the Canopy products

Configuration of the backhaul modules

Installation of the backhaul modules
Alignment
Unpack the Canopy Products
Upon receipt, carefully inspect all shipping boxes for signs of damage. If there is damage,
immediately notify the transportation company.
Unpack equipment, making sure that all ordered components have arrived. It is recommended that
you save all the packing materials. They can be used for transportation of the equipment to and
from installation sites.
Configuration of the Backhaul Modules
In all cases, when a configuration parameter is modified, the change must be saved and
the module must be rebooted.
All backhaul module, from the factory are configured as backhaul timing slaves. The following are
items that an operator will need to verify and/or configure for each module:
Will the module be a timing master or timing slave?
If it is a Timing Master
The are two methods that can be utilized to configure each of the backhaul timing masters. The
first method is to utilize the Quick Start feature of the product. For more information on Quick Start
see The Interface Screens. The second is to manually set each of the parameters.
Will the backhaul module need to generate its own sync pulse or will it receive it from the
cluster management module?
The operator will assign a RF frequency for the module to transmit.
The operator will assign an IP address to the module for the network it will be installed on
and assign an appropriate subnet mask and network gateway.
The operator must configure the appropriate color code on the backhaul timing master
module so that the backhaul timing slave module can register with it. The color codes
must match for registration.
If it is a Timing Slave
The backhaul timing slave module will utilize a network accessible IP address for its LAN
IP address. From the factory, the timing slave module is programmed to utilize an IP
address of 169.254.1.1. Continually, the appropriate subnet mask and default gateway
must be utilized for the operator network infrastructure.
The operator must configure the appropriate color code on the backhaul timing slave