Daikin CTXS07LVJU Service Manual page 120

Hide thumbs Also See for CTXS07LVJU:
Table of Contents

Advertisement

Service Diagnosis
3.2.2 BRC7E830
Relations
The following modes can be selected by using the INSPECTION/TEST button on the remote
controller.
Between Modes
Indoor unit settings can be made.
Filter cleaning sign time
Others
Following codes can be checked.
Error codes
Indoor model code
Service Check
To find the error code, proceed as follows:
Function
108
Press INSPECTION/TEST button
Field
setting
mode
Press INSPECTION/TEST
button for more than 4 seconds.
Press INSPECTION/TEST
button once.
Inspection
mode
Press INSPECTION/TEST button once.
Step
Action
Press INSPECTION/TEST button to enter the inspection mode. Then the figure 0 blinks on
1
the UNIT No. display.
for more than 4 seconds.
Service
mode
Press INSPECTION/TEST button once.
Normal
mode
Press INSPECTION/TEST button once or leave the remote
controller untouched for 30 minutes.
After 10 seconds
Test
operation
mode
INSPECTION/TEST button
Service data can be obtained.
Error code history
Temperature data of various sections
Service settings can be made.
Forced fan ON
Airflow rate setting
Thermostat is forcibly turned on.
(R23019)
(R14392)
Service Diagnosis
SiUS121602E