Potterton Promax HE Store Range User's Manual And Important Warranty Information page 11

Condensing boilers with integrated hot
Table of Contents

Advertisement

Fig. 10
M
RUN
AM
CLOCK
HW PROG
CH PROG
Fig. 11
M
RUN
CLOCK
PM
HW PROG
CH PROG
Fig. 12
M
RUN
CLOCK
HW PROG
CH PROG
Fig. 13
RUN
AM
CLOCK
HW PROG
CH PROG
Fig. 14
RUN
CLOCK
AM
HW PROG
CH PROG
© Baxi Heating UK Ltd 2013
T
W
T
F
S
S
HW CH
AUTO
ALL DAY
24 HR
OFF
T
W
T
F
S
S
HW CH
AUTO
ALL DAY
24 HR
OFF
T
W
T
F
S
S
HW CH
AUTO
ALL DAY
24 HR
OFF
M
T
W
T
F
S
S
HW CH
AUTO
ALL DAY
24 HR
ON
OFF
M
T
W
T
F
S
S
HW CH
AUTO
ALL DAY
24 HR
OFF
OFF
7.0 Programmer
ii) Use the PLUS (+) or MINUS (-) to move the DAY OF
THE WEEK INDICATOR to the current day of the week.
Numbers relating to the day of the week are printed
along the top of the programmer display, ie
1=Monday,
2=Tuesday and so on.
iii) Press the ENTER button. The TIME OF DAY will now
flash (Fig. 10).
iv) Now use the (+) or (-) BUTTONS to alter the display
to the correct time of day making sure that the AM/PM
SYMBOL is also correct (FIG. 11).
NOTE: By pressing and releasing the (+) or (-)
buttons you advance or retard the time in 1 minute
steps. If you keep the button depressed the display
will fast cycle and the time can be changed more
rapidly.
v) Press the ENTER button. Now use the SET BUTTON
to return the SET INDICATOR to the RUN POSITION.
7.4
Setting 'ON' & 'OFF' Times
NOTE: The minimum ON or OFF period that can be
set is ten minutes.
1. The integral programmer already has a factory pre-
set suite of ON/OFF times in its memory. These are:
Monday to Friday
Hot Water
1st ON
1st OFF
6.00 am
9.00 am
2nd ON
2nd OFF
12.00 pm
12.00 pm
3rd ON
3rd OFF
4.30 pm
11.00 pm
Saturday / Sunday
Hot Water
1st ON
1st OFF
7.00 am
10.30 am
2nd ON
2nd OFF
12.00 pm
1.00 pm
3rd ON
3rd OFF
4.00 pm
11.30 pm
2. If these settings do not meet your own requirements
then they can be easily changed as follows:
i) Press the SET BUTTON twice so that the SET
INDICATOR is in a PROG position (HW or CH). The
display will indicate the 'day' and the DAY OF THE
WEEK INDICATOR will now flash.
ii) Use the (+) or (-) BUTTONS to move the indicator to
the day of the week that you wish to change the times
for. Press ENTER. The display will show '1 ON' and
then first ON time for that day will flash (see Fig. 13).
iii) Adjust the flashing time as required by using the (+)
and (-) buttons then press ENTER. The display will now
show '1 OFF' and the first programmed OFF time for
the day will flash (see Fig. 14).
iv) This can now be altered in the same way as the
'1 ON' time mentioned above.
v) Follow the same procedure for the 2nd and 3rd
ON/OFF times remembering to press ENTER after each
change to the programme. If you do not wish to alter a
particular time then simply press ENTER and the
display will move on to the next ON/OFF time leaving
the previous one unchanged.
Central Heating
1st ON
1st OFF
6.30 am
9.00 am
2nd ON
2nd OFF
12.00 pm
12.00 pm
3rd ON
3rd OFF
5.00 pm
11.00 pm
Central Heating
1st ON
1st OFF
7.30 am
10.30 am
2nd ON
2nd OFF
12.00 pm
12.00 pm
3rd ON
3rd OFF
4.30 pm
11.30 pm
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents