Emergency Display Function - JVC HR-P201ER Service Manual

Table of Contents

Advertisement

2.3 Emergency display function

This unit saves details of the last two emergencies as the EMG
history and allows the status of the VCR and the mechanism of
each emergency to be shown both on the display and as OSD in-
formation.
When using the emergency function, it is required to set the VCR
to the Jig RCU mode (Refer to 2.5 Jig RCU mode).
Jig RCU
[Data transmitting method]
Depress the "
" ( 3 ) button
after the data code is set.
CUSTOM CODE
43: A
DATA CODE
Fig.2-3a
2.3.1 Displaying the EMG information
The EMG detail of information can be displayed by transmitting
the code "59" from the Jig RCU.
Note:
• The EMG detail information <1><2> show the informa-
tion on the latest EMG.
It becomes " – – : – – : – –" when there is no latest EMG
record.
0: 00
Normal display
E: * *
EMG content display (Latest)
1E: * *
EMG content display (Previous)
1: * 1
EMG detail information <1>
[Deck operation mode]
2: * 2
EMG detail information <1>
[Mechanism operation mode]
3: 34
EMG detail information <1>
[Mechanism sensor information and Mechanism mode position]
4: * 5
EMG detail information <2>
[Type of the cassette tape in use <1>]
5: * 6
EMG detail information <2>
[Winding position of the cassette tape in use]
6: * 7
EMG detail information <2>
[Type of the cassette tape in use <2> (Winding area)]
7: * 8
EMG detail information <3>
[Previous deck operation mode]
8: * 9
EMG detail information <3>
[The deck operation mode of the one before the last]
9: * 10
EMG detail information <3>
[The deck operation mode of the one prior to one above]
EMG display of 7segment LED display model
Fig.2-3-1b
0 : 00 : 00
Normal display (Counter or clock)
EMG content display (E:Latest:Previous)
E: * * : * *
[EMG code display mode]
*1: *2 : 34
EMG detail information <1> display
[Deck and other mode display mode]
EMG detail information <2> display
*5: *6 : *7
[Cassette display mode]
EMG detail information <3> display
*8: *9 : *10
[Deck mode history dispaly mode]
EMG display of FDP display model
Fig.2-3-1c
1-8 (No.82992)
INITIAL MODE
CODE
See 2.3.4
See 2.3.4
See 2.3.5
See 2.3.5
See 2.3.5
See 2.3.6
See 2.3.6
See 2.3.6
See 2.3.7
See 2.3.7
See 2.3.7
See 2.3.4
See 2.3.5
See 2.3.6
See 2.3.7
<Reference> EMG display of FDP display mode
(1) Transmit the code "59" from the Jig RCU.
The FDP shows the EMG content in the form of "E:**:**".
<Example 1>
E : 01 : 03
<Example 2>
E : - - : - -
(2) Transmit the code "59" from the Jig RCU again.
The FDP shows the EMG detail information <1> in the form
of " *1: *2 : 34 ".
*1 : Deck operation mode at the moment of EMG
*2 : Mechanism operation mode at the moment of EMG
3– : Mechanism sensor information at the moment of EMG
–4 : Mechanism mode position at the moment of EMG
(3) Transmit the code "59" from the Jig RCU once again.
The FDP shows the EMG detail information <2> in the form
of " *5 : *6 : *7 ".
*5 : Type of the cassette tape in use <1> .
*6 : Winding position of the cassette tape in use
*7 : Type of the cassette tape in use <2> (Winding area)
(4) Transmit the code "59" from the Jig RCU once again.
The FDP shows the EMG detail information <3> in the form
of "*8 : *9 : *10".
*8 : Previous deck operation mode at the moment of EMG
*9 : The deck operation mode of the one before the last at
the moment of EMG
*10: The deck operation mode of the one prior to one
above at the moment of EMG
(5) Transmit the code "59" from the Jig RCU once again to re-
set the display.
Previous EMG
Latest EMG
No EMG record