1.0 IMPORTANT INSTALLATION POINTS 2.0 INSTALLATION - MOUNTING 1.1 The Supreme stores and dispenses water at or close to boiling 2.1 The Supreme must be vertically wall mounted using the brackets point at all times it is switched on. Due caution must be taken supplied.
Page 4
2.7 The bracket bolted to the CASE BACK of the Supreme uses the M10 x 20 set screws (2 off) supplied. The small, slotted, CASE BACK bracket is secured in position with No. 8 x ½” screws (supplied). Note orientation and slot in the case anchor strap before fitting screws (Fig. 1). 2.8 Fit the 2 metal and black plastic stabilisers to the M6 threaded inserts (on the back of the unit 130mm above the base) and screw fully in.
Bottom inlet, rear vent 15mm x 15mm elbow 6.5 Connect the cable to the terminal block as follows: (Heatrae Sadia part no. 95 607 510) BROWN or RED wire to terminal marked L. Rear inlet, bottom vent 15mm x 15mm straight BLUE or BLACK wire to terminal marked N.
7.0 COMMISSIONING 8.0 MAINTENANCE 7.1 The electronic control system of the Supreme has a self NOTE: Maintenance must be carried out by competent persons. commissioning and calibration function. Once the heater is Competent - i.e. trained, experienced, qualified. Disconnect the electrical supply before removing the covers. installed and all services have been connected, the unit should WARNING: electronics control by switching ‘N’...
9.0 FAULT FINDING SAFETY NOTE: DISCONNECT THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVERS AND CARRYING OUT ANY OF THE FOLLOWING ACTIONS. DO NOT BYPASS ANY SAFETY CONTROLS. Any faults that cannot be identified using the Fault Finding chart, or in case of doubt, contact the Heateam Service Department (contact details on the back page.)
Push fit connector 15x15 straight 95 607 509 DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY 33. Push fit connector 15x15 elbow 95 607 510 HEATRAE SADIA - THIS WILL INVALIDATE YOUR GUARANTEE Fitting kit 95 607 023 AND MAY RENDER THE INSTALLATION DANGEROUS. Blanking plug 95 605 100 Element plate (3kW)
11.0 USER INSTRUCTIONS Warning - dispensed water is scalding hot - tap body reaches water temperature 11.1 Once installed, the filling and heating cycles of the Supreme are completely automatic. 11.2 To dispense the water, the tap handle should be pulled down and towards the user, a suitable container having been placed under the outlet spout.
4. The unit has been used only for heating potable water. The unit is not guaranteed against damage by frost or due to the build up of scale. Please note that if Heatrae Sadia personnel or agents are requested to descale a unit, this work will be chargeable.