MCZ EGO AIR Use And Maintenance Manual

MCZ EGO AIR Use And Maintenance Manual

Hide thumbs Also See for EGO AIR:
Table of Contents

Advertisement

USE AND MAINTENANCE
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for MCZ EGO AIR

  • Page 1 USE AND MAINTENANCE MANUAL...
  • Page 2 MCZ S.p.A. - Via G.Oberdan 86, I - 33074 Vigonovo (PN) Italy. EN 14785 - 2006 Art. 15a B-VG - VKF AEAI Regensburger und M ünchener BStV erfüllt. EGO AIR / STAR AIR Potencia nominal: 8,0 kW Potência nominal: Nominal heat output: 2,4 kW Brændværdi:...
  • Page 3: Table Of Contents

    External environment thermostat connection..............34 4.7.3.2. Automatic mode with AUTO-ECO .....................35 4.7.4. Activation /de-activation of AUTO-ECO mode ..............36 4.7.4.1. HOT AIR VENTILATION .........................37 4.8. SLEEP FUNCTION .........................38 4.9. TIMER ............................38 4.10. Contents Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 4 Cleaning of the heat exchanger ....................49 5.2.1. Shutting the stove down (end of season) .................50 5.2.2. Check of internal components ....................50 5.2.3. 6. PROBLEMS / CAUSES / SOLUTIONS ....................51 7. ELECTRICAL DIAGRAMS ........................53 Contents Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 5: Introduction

    INTRODUCTION Dear Customer, We wish to thank you for choosing an MCZ product, specifically a stove of the MCZ pellet line. In order to get the best performance from your stove and to enjoy to the full the warmth and the sense of well-being which...
  • Page 6: Warnings And Guarantee Conditions

    Danger of fire. • All responsibility for improper use is taken entirely by the user and such use relieves MCZ of any civil or criminal responsibility. • Any kind of tampering or unauthorised substitution of...
  • Page 7: Operating Warnings

    INFORMATION • In case of any problems, get in touch with your dealer, or a qualified engineer authorised by MCZ, and if a repair is necessary, insist on the use of original spare parts. • Use only the fuel recommended by MCZ (for Italy pellets Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A.
  • Page 8: Guarantee Conditions

    MCZ's specification (see the relevant chapters in this user manual). MCZ refuses to accept any responsibility for any damage which may be caused, directly or indirectly, by persons, animals or things in consequence of the failure to observe all the prescriptions laid down in Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A.
  • Page 9 For all replacement of parts, only original MCZ spare parts must be used. Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 10: Theoretical Notions For Installation

    Length: max 30mm Contents: 100% untreated wood, with no added bonding substances (bark percentage 5% max) Packaging: in sacks made from ecologically compatible or biologically decomposing material Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 11: Precautions For Installation

    (about 40 m /h must be Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 12: Connection To The External Air Intake

    • be positioned in such a way as to be impossible to obstruct Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 13: Connection Of Smoke Discharge Pipe

    USED AND NOT MORE THAN THREE 90° CURVES MUST BE USED IT IS ALSO ADVISABLE NOT TO EXCEED 6 METRES IN LENGTH WITH THE PIPE Ø 80 mm Example of pellet stove installation Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 14: Connection To The Flue Pipe

    You must ensure that a windproof cowl should be fitted which complies 1) Windproof cowl with the standards in force. 2) Flue pipe 3) Inspection Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 15: Operating Problems Caused By Draught Defects In The Flue

    Hazardous conditions can only be overcome by suitable setting-up of the stove carried out by qualified MCZ personnel. Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 16: Installation And Assembly

    INSTALLATION AND USE MANUAL page 3. INSTALLATION AND ASSEMBLY DRAWINGS AND TECHNICAL CHARACTERISTICS 3.1. 3.1.1. STAR Air Ø80 Ø48 FILTRO 3.1.2. EGO Air 187 198 Ø48 Ø80 FILTRO Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 17: Technical Characteristics

    * Data that may vary depending on the type of pellets used. **Heatable volume based on demand of cal/m 40-35-30 (respectively 40-35-30 Kcal/h for m Appliance suitable for installation in a shared flue. Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 18: Preparation And Unpack Ing

    Their storage, disposal or possible recycling are therefore the responsibility of the final user, in compliance with current legislation on the subject. Do not store the stove unit or its cladding without their packaging. Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 19 1. Turn the feet clockwise to lower the stove 2. Turn feet counter- clockwise lower stove Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 20: Lateral Cladding Assembly

    In the front part it must be inserted in the housing (B3) of the profile (B). Repeat the same operation for both sides. Reposition the cast iron top. Figure 5 - EGO stove steel sides Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 21 Repeat the same operation for both sides. Reposition the cast iron top. Figure 6 - STAR stove sides Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 22: Installation Of Air Filter

    If you do not intend to use the stove, it is advisable to keep it switched off. Electrical connection of the stove Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 23: Operation

    Try to get familiar with the commands given from the control panel. Try to memorize the messages that the stove provides on the display. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 24: Pre-Lighting Check

    When filling, do not let the sack of pellets touch any hot surfaces. Do not place any type of fuel in the hopper other than pellets that are compliant with the specifications provided previously. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 25: Control Panel/Remote Control Display (Accessory)

    If from any menu level the on/off (B) key is briefly pressed, the display is automatically taken back to the initial screen (stove operating status) without saving any modifications not confirmed with the “OK” key. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 26 E. Programme selection key (next screen) F. Programme selection key (next screen) G. Receiver for the remote control N.B. on the control panel it will be possible to set the language Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 27: Remote Control (Accessory)

    N.B. from the remote control it is not possible to the AUTO function (key 7) activates, this means activate the ECO-STOP function that the ventilation is connected to the power. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 28: General Characteristics Of The Lcd Remote Control

    The switch located to the rear of the stove powers the system. The stove is off and on the panel the first screen appears with the word OFF; by pressing any key the screen with the word MENU will appear. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 29: Setting Current Day And Time

    TIME ADJUSTMENT 21.0°C 21.04 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A < Date setting > Hours Minutes Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 30 PELLET STOVES Chapter 4 INSTALLATION AND USE MANUAL page DAY/DAY NUMBER/MONTH/YEAR ADJUSTMENT 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A Lunedi < Date setting > Day of months Month 2008 Year Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 31: Setting The Language

    In the case of English: Monday Tuesday Wednesday Thursday Friday Saturday Sunday 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A < Setting > < Setting > < Language > < Language > Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 32: On/Off From The Control Panel Or Remote Control (If Purchased)

    AUTOMATIC mode, on the other hand, lets you set the desired temperature in the room of installation. The stove will control its power autonomously in order to reach and maintain the established Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 33: Manual Mode

    Menu hearing performance. Temp:20° Fan:2 The room temperature is highlighted by the control panel using the reading of the probe placed near the switch of the stove. Automatic mode Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 34: Room Sensor

    Fig. 8 - Motherboard (internal Fig.9 Interface stove) environment thermostat A = PROTECTION CAP B = PROBE (FLUSH) C = CLAMP INTERFACE EXTERNAL THERMOSTAT E = MOTHERBOARD CONNECTOR INTERFACE CONNECTION HOLES CABLE OUTLET Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 35: Automatic Mode With Auto-Eco

    This option is advisable only if the stove works in highly insulated rooms or where there is low heat dispersion over time. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 36: Activation /De-Activation Of Auto-Eco Mode

    Temp:22°C Fan:1 hot air. To disable the AUTO-ECO function follow the same procedure. Mode:ECO Menu Temp:22°C Fan:1 Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 37: Hot Air Ventilation

    In selecting the fan speed, it is advisable not to select very low speeds (1st or 2nd) when the stove is at maximum power as this may cause the structure to overheat. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 38: Sleep Function

    Current date and clock 4.10.1. paragraph 4.5.1. to learn how to set the current date and time. Setting the current date and time is essential for proper timer operation. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 39: Timer Activation And Selection Of A Programme

    By scrolling with the bottom right or left key of the control panel it is possible to choose the desired programme from 1 to 60, by consulting the table in par. 4.11. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 40: Pre-Set Weekly And Daily Programmes

    4.11. PRE-SET WEEKLY AND DAILY PROGRAMMES Weekly programmes 4.11.1. The weekly programmes selected by MCZ and stored in the memory of the control panel were designed to meet the needs of most users who are out of the home during working hours (factory workers, shopkeepers, office workers, shift workers) as well as those who are usually at home (homemakers, senior citizens, etc.).
  • Page 41 PELLET STOVES Chapter 4 INSTALLATION AND USE MANUAL page PROGRAMMES HOURS DAYS Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Sa Mon-Sa Mon-Sa Sa-Su Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 42: Daily Programmes

    PELLET STOVES Chapter 4 INSTALLATION AND USE MANUAL page Daily programmes 4.11.2. PROGR. HOURS N° Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 43: Practical Example Of Daily Programming

    • FAILURE OF THE SMOKE EXTRACTION FAN If the fan stops, the electronic board shuts off the supply of pellets in good time, and an alarm is displayed. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 44: Alarm Signalling

    The table below describes the possible alarms signalled by the stove, associated to the respective code that appears on the emergency panel, and useful suggestions to solve the problem. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 45 Contact an authorized service centre to replace the component. This alarm is not blocked, only a warning screen appears. Contact an authorized service centre to Generic failure of sensor replace the component. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 46: Exiting Alarm Condition

    Info ALARM A02 Flame extinction Example: Alarm on the display of the control panel ALARM Fill pellet tank Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 47: Maintenance And Cleaning

    It is however advisable not to let it exceed 2 or 3 days. Once the operation is finished, reinsert the ash drawer below the grate making sure it is well inserted Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 48: Cleaning The Glass

    If it is broken it must be replaced ATTENTION! Never operate the stove without the air filter. MCZ shall not be held liable for damage to internal components if this instruction is not followed. Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 49: Periodic Cleaning By A Specialised Technician

    “F” and clean it every 2/3 days as explained in chap. 5.1 It is worthwhile to carry out the cleaning of the upper exchanger at the end of the season and possibly by an authorised MCZ technician in order to replace the gaskets that are below plug “C” and “E”...
  • Page 50: Shutting The Stove Down (End Of Season)

    Glass ● Lower heat exchanger ● Complete exchanger ● Smoke duct ● Door seal ● ● Air filter ● Flue pipe ● Remote control battery (if purchased/optional) Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 51: Problems / Causes / Solutions

    • Check the state of the door gaskets. • Pellets damp or unsuitable. • Change the type of pellet. • Smoke extractor motor broken. • Check the motor and replace if necessary. Problems/Causes/Solutions Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 52 The operations marked in bold type must be carried out by specialised MCZ personnel. The manufacturer refuses to accept any responsibility and the guarantee lapses if this condition is not respected. Problems/Causes/Solutions Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 53: Electrical Diagrams

    6. Ignition plug 13. Manifold for environment thermostat interface 7. Flue-gas extractor fan N.B. The electrical wiring of the single components includes pre-wired connectors which are of different sizes. Electrical diagrams Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
  • Page 54 MCZ S.p.A. Via Guglielmo Oberdan n°86 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: 0434/599599 r.a. Fax: 0434/599598 Internet: www.mcz.it e-mail: mcz@mcz.it 8900903800 Rev 1 07/2009...

This manual is also suitable for:

Star air

Table of Contents