INTRODUCTION Dear Customer, We wish to thank you for choosing an MCZ product, specifically a stove of the MCZ pellet line. In order to get the best performance from your stove and to enjoy to the full the warmth and the sense of well-being which...
Danger of fire. • All responsibility for improper use is taken entirely by the user and such use relieves MCZ of any civil or criminal responsibility. • Any kind of tampering or unauthorised substitution of...
INFORMATION • In case of any problems, get in touch with your dealer, or a qualified engineer authorised by MCZ, and if a repair is necessary, insist on the use of original spare parts. • Use only the fuel recommended by MCZ (for Italy pellets Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A.
MCZ's specification (see the relevant chapters in this user manual). MCZ refuses to accept any responsibility for any damage which may be caused, directly or indirectly, by persons, animals or things in consequence of the failure to observe all the prescriptions laid down in Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A.
Page 9
For all replacement of parts, only original MCZ spare parts must be used. Warnings and guarantee conciliations Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Length: max 30mm Contents: 100% untreated wood, with no added bonding substances (bark percentage 5% max) Packaging: in sacks made from ecologically compatible or biologically decomposing material Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
• be positioned in such a way as to be impossible to obstruct Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
USED AND NOT MORE THAN THREE 90° CURVES MUST BE USED IT IS ALSO ADVISABLE NOT TO EXCEED 6 METRES IN LENGTH WITH THE PIPE Ø 80 mm Example of pellet stove installation Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
You must ensure that a windproof cowl should be fitted which complies 1) Windproof cowl with the standards in force. 2) Flue pipe 3) Inspection Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Hazardous conditions can only be overcome by suitable setting-up of the stove carried out by qualified MCZ personnel. Theoretical notions for installation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
INSTALLATION AND USE MANUAL page 3. INSTALLATION AND ASSEMBLY DRAWINGS AND TECHNICAL CHARACTERISTICS 3.1. 3.1.1. STAR Air Ø80 Ø48 FILTRO 3.1.2. EGO Air 187 198 Ø48 Ø80 FILTRO Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
* Data that may vary depending on the type of pellets used. **Heatable volume based on demand of cal/m 40-35-30 (respectively 40-35-30 Kcal/h for m Appliance suitable for installation in a shared flue. Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Their storage, disposal or possible recycling are therefore the responsibility of the final user, in compliance with current legislation on the subject. Do not store the stove unit or its cladding without their packaging. Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 19
1. Turn the feet clockwise to lower the stove 2. Turn feet counter- clockwise lower stove Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
In the front part it must be inserted in the housing (B3) of the profile (B). Repeat the same operation for both sides. Reposition the cast iron top. Figure 5 - EGO stove steel sides Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 21
Repeat the same operation for both sides. Reposition the cast iron top. Figure 6 - STAR stove sides Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
If you do not intend to use the stove, it is advisable to keep it switched off. Electrical connection of the stove Installation and fitting Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Try to get familiar with the commands given from the control panel. Try to memorize the messages that the stove provides on the display. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
When filling, do not let the sack of pellets touch any hot surfaces. Do not place any type of fuel in the hopper other than pellets that are compliant with the specifications provided previously. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
If from any menu level the on/off (B) key is briefly pressed, the display is automatically taken back to the initial screen (stove operating status) without saving any modifications not confirmed with the “OK” key. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 26
E. Programme selection key (next screen) F. Programme selection key (next screen) G. Receiver for the remote control N.B. on the control panel it will be possible to set the language Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
N.B. from the remote control it is not possible to the AUTO function (key 7) activates, this means activate the ECO-STOP function that the ventilation is connected to the power. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
The switch located to the rear of the stove powers the system. The stove is off and on the panel the first screen appears with the word OFF; by pressing any key the screen with the word MENU will appear. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
TIME ADJUSTMENT 21.0°C 21.04 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A < Date setting > Hours Minutes Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 30
PELLET STOVES Chapter 4 INSTALLATION AND USE MANUAL page DAY/DAY NUMBER/MONTH/YEAR ADJUSTMENT 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A Lunedi < Date setting > Day of months Month 2008 Year Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
In the case of English: Monday Tuesday Wednesday Thursday Friday Saturday Sunday 21.0°C 21.04 Mode:AUTO Menu Temp:22°C Fan:A < Setting > < Setting > < Language > < Language > Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
AUTOMATIC mode, on the other hand, lets you set the desired temperature in the room of installation. The stove will control its power autonomously in order to reach and maintain the established Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Menu hearing performance. Temp:20° Fan:2 The room temperature is highlighted by the control panel using the reading of the probe placed near the switch of the stove. Automatic mode Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
This option is advisable only if the stove works in highly insulated rooms or where there is low heat dispersion over time. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Temp:22°C Fan:1 hot air. To disable the AUTO-ECO function follow the same procedure. Mode:ECO Menu Temp:22°C Fan:1 Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
In selecting the fan speed, it is advisable not to select very low speeds (1st or 2nd) when the stove is at maximum power as this may cause the structure to overheat. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Current date and clock 4.10.1. paragraph 4.5.1. to learn how to set the current date and time. Setting the current date and time is essential for proper timer operation. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
By scrolling with the bottom right or left key of the control panel it is possible to choose the desired programme from 1 to 60, by consulting the table in par. 4.11. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
4.11. PRE-SET WEEKLY AND DAILY PROGRAMMES Weekly programmes 4.11.1. The weekly programmes selected by MCZ and stored in the memory of the control panel were designed to meet the needs of most users who are out of the home during working hours (factory workers, shopkeepers, office workers, shift workers) as well as those who are usually at home (homemakers, senior citizens, etc.).
Page 41
PELLET STOVES Chapter 4 INSTALLATION AND USE MANUAL page PROGRAMMES HOURS DAYS Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Fri Sa-Su Mon-Sa Mon-Sa Mon-Sa Sa-Su Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
• FAILURE OF THE SMOKE EXTRACTION FAN If the fan stops, the electronic board shuts off the supply of pellets in good time, and an alarm is displayed. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
The table below describes the possible alarms signalled by the stove, associated to the respective code that appears on the emergency panel, and useful suggestions to solve the problem. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 45
Contact an authorized service centre to replace the component. This alarm is not blocked, only a warning screen appears. Contact an authorized service centre to Generic failure of sensor replace the component. Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Info ALARM A02 Flame extinction Example: Alarm on the display of the control panel ALARM Fill pellet tank Operation Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
It is however advisable not to let it exceed 2 or 3 days. Once the operation is finished, reinsert the ash drawer below the grate making sure it is well inserted Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
If it is broken it must be replaced ATTENTION! Never operate the stove without the air filter. MCZ shall not be held liable for damage to internal components if this instruction is not followed. Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
“F” and clean it every 2/3 days as explained in chap. 5.1 It is worthwhile to carry out the cleaning of the upper exchanger at the end of the season and possibly by an authorised MCZ technician in order to replace the gaskets that are below plug “C” and “E”...
• Check the state of the door gaskets. • Pellets damp or unsuitable. • Change the type of pellet. • Smoke extractor motor broken. • Check the motor and replace if necessary. Problems/Causes/Solutions Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
Page 52
The operations marked in bold type must be carried out by specialised MCZ personnel. The manufacturer refuses to accept any responsibility and the guarantee lapses if this condition is not respected. Problems/Causes/Solutions Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...
6. Ignition plug 13. Manifold for environment thermostat interface 7. Flue-gas extractor fan N.B. The electrical wiring of the single components includes pre-wired connectors which are of different sizes. Electrical diagrams Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited...