11.5. Valve
Valve is an electrical and mechanical component which is
designed to take water from the network system into the
washine machine. It is operated by PCB card.
Nominal voltage
Nominal power
Frequency
Check the resistance value on the component with multimeter as shown below. Valve water flow rate should be between
You can determine the resistance value of the main wash valve by measuring from the blue cable at 5th and white cable at 15th
position or the pre-wash valve by measuring from the black cable at 14th and white cable at 15th position in the large socket
(refer wiring diagram in section 12) as shown in below figure. Each valve coil resistance values should be between 3.3 - 4.2
Technical features
220-240 V
8 VA
50-60 Hz
Testing component
6 - 8 L/min. Each valve coil resistance values should be between 3.3 - 4.2 k
147VB5WDE / 147VB5WGB / 147VB5WGN / 147VB5WNR
Rated flow
Operating water pressure
kohm.
Component test
33
7 L/min (±15 %)
0.03 - 1 Mpa