Download Print this page

Technical Data - Whirlpool FL 5085 Service Manual

Advertisement

11.11.2002 / Page 2
Doc. No: 4812 712 17681

Technical data

Dimensions
Height
Width
Depth
Weight
Net weight
With package
Main Connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Ramp speed
Speed spinning max.
Capacity of dry laundry
Cotton/coloured
Cotton rapid
Cotton short
Easy care
Easy care rapid
Easy care short
Delicate
Wool
Handwash/Silk
Pressostat
Kind of switch
Type
Nominal voltage
Water Level
Level 1 (11 - 12, 14)
Switching point
Switching back point
Overflow (11 - 16)
Water level based
to drum
FL 5085
8570 508 10050
85
cm
59.5
cm
54
cm
~67
kg
~71
kg
V ± 10%
230
50
Hz
~2.3
kW
10
A
42
l
54
rpm
95
rpm
840
rpm
5
kg
3
kg
3
kg
2.5
kg
1.5
kg
2.5
kg
1.5
kg
1
kg
1
kg
1-level pressoswitch
with overflow contact
B1-205
230
V
50 ± 5
mmWc
30 ± 5
mmWc
300 ± 20 mmWc
80 ± 10
mm
Whirlpool Europe
Customer Service
Nominal currents
Contacts
11 - 12
11 - 14
11 - 16
Door lock
Kind of switch
Type
Nominal voltage
Nominal current:
Contact 4 - 5
Lock time
Unlock time
Heating element
Kind of heating
Nominal voltage
Nominal power
Resistance (20 ˚C)
Thermo-fuse (switch
OFF temperature)
Leakage current (<99 ˚C)
NTC sensor
Class of protection
Resistance NTC :
0˚C
30˚C
40˚C
50˚C
60˚C
70˚C
95˚C
Inlet valve
Kind of valve
Water temperature
Rated flow >1 bar
Pressure range
Nominal voltage
Frequency
Nominal current
Nominal power
Nominal resistance
S E R V I C E
4 (4)
A
16 (4)
A
1 (1)
A
Blocking limit switch
with PTC heater of
Bimetal
BP P/5 - R
230
V
16 (4)
A
≤6''
≤180''
Tubular heating element
with NTC - sensor
230 ± 10%, -15% V
W ± 5%
2050
Ω ± 5%
23.9
152
˚C
<0.8
mA
II
kΩ ± 5.8%
35.9
kΩ ± 3.7%
9.8
kΩ ± 3.1%
6.6
kΩ ± 2.6%
4.6
kΩ ± 2.0%
3.2
kΩ ± 2.5%
2.3
kΩ ± 3.7%
1.1
1-way valve for cold
water with Rast 2.5
electrical connection
<60
˚C
l/min ± 15%
8
0,2 - 10
bar
220 - 240 V
50
Hz
35
mA
W ± 10%
7 .7
kΩ ± 10%
3.8

Hide quick links: