Check Thermostat Operation; Fan Operation; Heating System - White Rodgers 1F92-71 Installation Instructions Manual

Hide thumbs Also See for 1F92-71:
Table of Contents

Advertisement

5. Economizer — 1st stage cooling
When using economizer with
W1
Y2
single stage heat pump, field
jumper W1 & Y2
Switch #1 (see steps 1-4)
ON
Switch #2 (see steps 1-4)
Switch #3
Switch #4 (see step 6)
1
2
3
4
6. Automatic Changeover from Heat to Cool
Switch #1 (see steps 1-4)
ON
Switch #2 (see steps 1-4)
Switch #3 (see step 5)
Switch #4 ON
1
2
3
4
NOTE
The battery maintains the stored program in the event of
a power failure. When attached to the wall with 24vAC
power applied, the thermostat will function normally with-
out the battery. However, the program will be lost in the
event of power interruption or failure if the battery is not
installed. When power is restored, the thermostat will
automatically maintain a temperature of 64°F or a cooling
temperature of 82°F (factory preprogrammed) as needed.

CHECK THERMOSTAT OPERATION

NOTE
When checking thermostat, option switch #4 for auto-
matic changeover must be in the OFF position. This will
allow temporary setting of heat set points above cool
settings. After system checkout, reset option switch to ON
position if automatic changeover is desired (see SET
OPTION SWITCHES).

FAN OPERATION

1. Turn on power to the system. If the auxiliary heat
source has a standing pilot, be sure to light it.
2. Press
FAN
until FAN
SWITCH
should begin to operate.
3. Press
FAN
until FAN
SWITCH
should stop operating within approximately one
minute.

HEATING SYSTEM

SYSTEM
1. Press
until HEAT is displayed. (It may
SWITCH
already be displayed.)
ON
is displayed. The blower
is displayed. The blower
LOCKOUT BYPASS OPTION
CAUTION
!
FOR QUALIFIED SERVICE TECHNICIANS' USE
ONLY. OPERATORS SHOULD NOT USE THIS
FEATURE DUE TO POSSIBILITY OF EQUIPMENT
OR PROPERTY DAMAGE, OR PERSONAL INJURY.
DO NOT USE THE LOCKOUT BYPASS OPTION
UNLESS THE COMPRESSOR OIL HEATERS HAVE
BEEN OPERATIONAL FOR 6 HOURS AND THE
SYSTEM HAS NOT BEEN OPERATIONAL FOR AT
LEAST 5 MINUTES.
COMPRESSOR LONG TERM CYCLE
PROTECTION
To protect the compressor from potential damage due
to temperature change of crankcase oil, this thermo-
stat has a built-in time delay of one hour less than the
power loss to the unit (up to 12 hours maximum
lockout). During this time, auxiliary heat will be used
when necessary to maintain setpoint temperature.
DO NOT attempt to override this delay feature before
crankcase temperature has stabilized (for example, if
power has been out for three hours, the compressor
should remain locked out for two hours).
COMPRESSOR SHORT TERM CYCLE
PROTECTION
This thermostat has a built-in short term (5-minute)
time delay. During this 5-minute period, the thermo-
stat will lock out the compressor to allow head pres-
sure to stabilize. If you want to override this feature
while testing thermostat operation, simply press
HOLD
and
at the same time at initial startup.
TEMP
2. Press
to adjust thermostat to 99°F. All stages
of the heating system should come on within approxi-
mately five minutes. However, if the PUMP LED is
flashing, the compressor lockout feature is operating
(see Lockout Bypass Option to temporarily over-
ride the compressor lockout feature during testing).
SYSTEM
3. Press
until EMER is displayed. Repeat step
SWITCH
2.
4. To program the thermostat, see OPERATION GUIDE.
(Instructions continue on next page)
ADV
PRGM
7