Tuner Section - Sony XR-C8220R Service Manual

Fm/mw/lw cassette car stereo
Hide thumbs Also See for XR-C8220R:
Table of Contents

Advertisement

QQ
3 7 63 1515 0

TUNER SECTION

Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note: Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment
2. FM Stereo Separation Adjustment (Wide)
3. FM Stereo Separation Adjustment (Narrow)
4. FM RDS S-Meter Adjustment
5. MW Auto Scan/Stop Level Adjustment
FM Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
button : FM
FM RF signal
generator
Carrier frequency
Output level
Mode
Modulation
Procedure:
1. Set to the test mode. (See page 18)
[SOURCE]
2. Push the
TE
L 13942296513
[3]
3. Push the preset
4. Adjust with the volume RV2 on TUX10 so that the "FM" indi-
cation turns to "FM0" indication on the display window.
But, in case of already indicated "FM0", turn the RV2 so that
put out light "0" indication and adjustment.
www
Adjustment Location: See page 22.
.
http://www.xiaoyu163.com
0 dB=1 µV
antenna jack
0.01 µ F
set
: 98.00 MHz
: 22 dB (12.6 µ V)
: mono
: 1 kHz, 22.5 kHz deviation (30%)
button and set to FM.
Display
SHUF
button.
Display
SHUF
Display
SHUF
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
FM Stereo Separation Adjustment (Wide)
Setting:
[SOURCE]
button
[SHIFT]
button
[4]
Preset
(PLAY MODE)
[5]
n
(n) buttons
FM RF signal
generator
0.01 µ F
Carrier frequency : 98.00 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main : 1 kHz, 33.75 kHz deviation (45%)
:
Procedure:
FM Stereo
signal generator
output channel
L-CH
R-CH
R-CH
Q Q
L-CH
3
6 7
1 3
1 5
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 24 dB
Adjustment Location: See page 22.
co
.
– 19 –
9 4
2 8
: FM
: ON (light up SET UP and
PLAY MODE)
: WIDE mode
antenna jack
10 k Ω
set
LINE OUT REAR jack
(CN780)
sub : 1 kHz, 33.75 kHz deviation (45%)
19 kHz pilot: 7.5 kHz deviation (10%)
Level meter
Level meter
connection
reading (dB)
L-CH
L-CH
Adjust RV3 on TUX10
for minimum reading.
R-CH
R-CH
Adjust RV3 on TUX10
0 5
8
2 9
9 4
2 8
for minimum reading.
m
9 9
level meter
+
A
B
C
D
9 9