Common Section
Item
Condition
1. Setting
1) Power supply voltage
DC power supply terminal : 7.5V
2. Receive
1) Auto tuning
Assist
*Note
Voltage
2) CH: Low
3. Transmit
1) Auto tuning
Assist
*Note
Voltage
2) CH: Low
*Note: At test mode, click [Tune Assist Voltage] button in test mode dialog box, then start automatic adjustment of Receive/Transmit assist voltage.
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: Center
PTT: ON
2. High Power
1) TEST CH: Low, Low', Center,
High', High (5 points)
2) BATT terminal voltage: 7.5V
3) PTT: ON
3. Low Power
1) TEST CH: Low, Center, High
(3 points)
2) BATT terminal voltage: 7.5V
3) PTT: ON
4. DQT
1) TEST CH: Low, Low', Center,
Balance 2
High', High (5 points)
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) PTT: ON
5. Maximum
1) TEST CH: Center, Low, Low',
Deviation
High, High' (5 points)
*Note
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) PTT: ON
TK-2402(V)/2402/2406/2407
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Digital
ANT
TX-RX FPU
Voltage
Multimeter
TX-RX
CVIN
TX-RX FPU
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter
ANT
TX-RX FPU
Power
meter
Ammeter
Deviation
ANT
meter
Oscilloscope
Adjustment
Parts
Method
4.0V±0.1V
Check
0.6V or more
4.0V±0.1V
Check
0.6V or more
Adjustment
Parts
Method
155.100MHz
±50Hz
FPU
5.0W
±0.1W
2.0A or less
1.0W
±0.1W
1.0A or less
The Deviation of
±0.2dB
20Hz frequency is
fi xed.
Change the 1kHz
adjustment value to
become the same
deviation of 20Hz
within the specifi ed
range.
2.0kHz (According
±50Hz
to larger +, –)
Note:
FPU AUTO INPUT
1kHz/150mV
Specifi cations / Remarks
Specifi cations / Remarks