Adjustment Process Mode Menu - Sharp LC-40LE730E Service Manual

Hide thumbs Also See for LC-40LE730E:
Table of Contents

Advertisement

LC-40LE730
LC-46LE730

5. Adjustment process mode menu

Sub
page
Page
Line
1
2
3
4
5
2/8
6
3/8
7
4/8
8
5/8
9
6/8
Item
Main Version
LE730E v1.253 790.173.78 v14 Informative only (Main microprocessor version)
FRC
HardwareVersion
None / Remote Control /
Normal Standby Cause
INIT
Factory Init
Inch Setting
Center Acutime
RESET
TUNER
EEP, Autoinstallation, Option,
ETC
EEP Clear
EEP Clear B
Standby cause reset
Autoinstallation SW
Pattern
L Error Counter
L Error Reset
PUBLIC MODE
PUBLIC MODE Submenu
Power On fixed
Maximum volume
Volume fixed
Volume fixed Level
RC button
Panel button
Menu button
Input mode start
Input mode fixed
Input TV mode program
number
RC path through
Hotel mode
Reset
Commit
On screen display
SMART LOADER
SMART LOADER Submenu
Save settings to USB
"Wait..." and "OK" when finish
Load settings from USB
"Wait..." and "OK" when finish
ADC ADJUST
ADC ADJUST Submenu
MODE
ADJUST
R-GAIN
Description
Remarks (adjustment details, etc.)
2.3.0.180.390-290
Informative only (FRC version)
SHARP 691
Informative only
Keyboard...
Informative only
Factory Init Submenu
Press "►" or "OK" to enter to Factory Init Submenu
Informative (EURO/RUSSIA/NORDIC/UK/EAST
EUROPE)
EURO
40"
Panel type (40" / 46")
0 H 0 M
Backlight ON accumulated Time
Press "►" to reset Center Acutime
NuTUNE
Press "►" or "OK" to slect (Nutune / LG)
Country, L Error...
Press "►" or "OK" to enter to ETC Submenu
Press "►" to Clear NVM data
Press "►" to Clear NVM data (except adjustments
area).
Press "►" to Reset of STANDBY CAUSE.
Off
0
Selection of internal pattern from 0 to 6
0
Function is not available
Function is not available
Press "►" or "OK" to enter to PUBLIC MODE
Submenu
Variable
Press "►" to change Variable/Fixed.
60
Press "►" to change 0/60.
Variable
Press "►" to change Variable/Fixed.
20
Press "►" to change 0/60.
Respond
Press "►" to change Respond/No respond.
Respond
Press "►" to change Respond/No respond.
Respond
Press "►" to change Respond/No respond.
Normal
Press "►" to change Normal/TV/SCART/...
Variable
Press "►" to change Variable/Fixed.
0
Press "►" to change 0 → 1 → 2 ...999 ).
Press "►" to change On/Off (required external
module)
Off
Off
Press "►" to change On/Off.
Press "►" to return to factory settings.
Press "►" to confirm.
On
Press "►" to change On/Off.
Press "►" or "OK" to enter to SMART LOADER
Submenu
Press "►" to Save.
the process
Press "►" to Load.
the process
Press "►" or "OK" to enter to ADC ADJUST
Submenu
YPbPr(SD)
Only for Engineering purpose (Please don't use)
Int. signal
Only for Engineering purpose (Please don't use)
272
Only for Engineering purpose (Please don't use)
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-46le730ruLc-40le730ruLc-46le730e

Table of Contents