Pioneer PDP-5030HD Product Training Manual page 42

Hide thumbs Also See for PDP-5030HD:
Table of Contents

Advertisement

Timing Adjustment of X and Y DRIVE Assys Control Signal
Purpose
• Pulse module loads in DRIVE Assy is one of heat measures of DRIVE Assy. Adjust the drive timing of the pulse module
driving parallel with VR.
• Pulse module has each peculiar delay time. Readjustment is necessary when replacing the pulse module in the X and
Y DRIVE Assys.
Adjustment Method
CR delay circuit is each inserted on signal path of four control signals (SUS-U, SUS-B, SUS-D, SUS-G) driving
the pulse module.
Quantity of delay can adjust pulse module of one side with VR.
Adjust VR while measuring a waveform of the pulse module, and match timing.
Adjustment VR
X DRIVE
Y DRIVE
SUS-U
VR3203
SUS-D
VR3202
SUS-B
VR3201
SUS-G
VR3200
Adjustment Procedure
Power ON
Black Mask Screen
Display a SUSOUT waveform
Coarse adjustment of
SUS-U, SUS-B, SUS-G
Display a SUS-D waveform
SUS-D adjustment
Adjust the waveform to 20-25ns.
Display a SUS-U waveform
SUS-U adjustment
Adjust the waveform to 20-25ns.
Power OFF
Adjust VR resistance value
of SUS-B and SUS-G to match
VR resistance value of SUS-D
within ± 2Ω.
PDP-433PU
VR2204
VR2203
VR2202
VR2201
Measuring points of waveform
are refered to next page.
Test pin for adjustment and measurment
Pulse Module
X DRIVE
Upper
SUSOUT
K3105
SUS-U
K3200
SUS-D
K3108
Power ON and
display a SUS-D waveform
SUS-D readjustment
Adjust the waveform to 20-25ns.
Display a SUS-U waveform
SUS-U readjustment
Adjust the waveform to 20-25ns.
Power OFF
Adjust VR resistance value
of SUS-B and SUS-G to match
VR resistance value of SUS-D
within ± 2Ω.
Power ON and display a SUSOUT
waveform
No
Compare waveforms,
Should look almost
the same?
Yes
Adjustment end
Y DRIVE
Lower
Upper
Lower
K3106
K2212
K2203
K3204
K2220
K2224
K3205
K2207
K2225
42.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-4330hd

Table of Contents