Model name
Indoor unit
Outdoor unit
Max. Capacity
Cooling
Rated Capacity
Min. Capacity
Total Input
EER
SEER
Moisture Removal
*1 SHF
Max. Capacity
Heating
Rated Capacity
Min. Capacity
Total Input
COP
*1 HSPF (4/5)
Rated Capacity
Heating
Total Input
at low ambient
*2 COP
Phase, Cycle, Voltage
Power supply
Breaker size
Indoor - Outdoor S1-S2
Voltage
Indoor - Outdoor S2-S3
Indoor - Remote Controller
MCA
Indoor unit
MOCP
Fan Motor
Fan Motor Output
Air flow
(Lo-M2-M1-Hi) WET
Air flow
(Lo-M2-M1-Hi) WET
External pressure
Sound level
(Lo-M2-M1-Hi)
External finish (Panel)
Dimension
Unit (Panel)
Weight
Unit (Panel)
Field drain pipe size O.D.
Remote Controller
MCA
Outdoor unit
MOCP
Fan Motor
Fan Motor Output
Compressor
Air flow
Refrigerant Control
Defrost Method
Sound level at cooling
Sound level at heating
External finish
Dimension
Weight
Type
Refrigerant
Charge
Oil
Gas side O.D.
Refrigerant pipe size
Liquid side O.D.
Height difference
Refrigerant pipe length
Length
Refrigerant Piping
Connection Method
NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7:(80°F), W.B. 19.4:(67°F)
(heating)-Indoor : D.B. 21.1:(70°F), W.B. 15.6:(60°F)
*2.Rating conditions(heating)-Indoor : D.B. 21.1:(70°F), W.B. 15.6:(60°F)
Operating range
Maximum
Cooling
Minimum
Maximum
Heating
Minimum
* In case that the wind baffle is installed. (In case that the wind baffle is not installed, the minimum temperature will be -5:(23°F)DB.)
8
Btu/h
Btu/h
Btu/h
W
Btu/h/W
Btu/h/W
Pints/h
Btu/h
Btu/h
Btu/h
W
W/W
Btu/h/W
Btu/h
W
W/W
A
A
A
F.L.A.
W
DRY
CMM
CMM
DRY
CFM
CFM
Pa
dB(A)
W : mm [inch]
D : mm [inch]
H : mm [inch]
kg
lbs
mm [inch]
A
A
F.L.A.
W
R.L.A
L.R.A.
CMM [CFM]
dB(A)
dB(A)
W : mm [inch]
D : mm [inch]
H : mm [inch]
kg [lbs]
kg [lbs]
L [oz]
mm [inch]
mm [inch]
Indoor intake air temperature
D.B.
35:(95°F), W.B. 21.7:(71°F)
D.B. 19.4:(67°F), W.B. 13.9:(57°F)
D.B. 26.7:(80°F), W.B. 19.4:(67°F)
D.B. 21.1:(70°F), W.B. 15.6:(60°F)
PCA-A24KA
PCA-A30KA
PUZ-A24NHA3
PUZ-A30NHA3
PUZ-A24NHA3-BS
PUZ-A30NHA3-BS
24,000
30,000
24,000
30,000
12,000
12,000
2340
3760
10.3
8.0
16.8
14.5
5.8
8.3
0.73
0.69
28,000
34,000
26,000
32,000
12,000
12,000
2310
3210
3.30
2.92
10.9 / 8.9
9.2 / 7.1
18,000
23,000
2220
2940
2.38
2.29
1phase , 60Hz , 208/230V
25
1
0.54
95
15-16-17-19
16-17-18-20
14-15-16-18
15-16-17-19
530-565-600-670
565-600-635-705
495-530-565-635
530-565-600-670
33-35-37-40
35-37-39-41
White Munsell 6.4Y 8.9/0.4
1280 [50-3/8]
32
71
18
30
0.75
75
TNB220FLHM
12
14
55 [1,940]
48
50
943 [37-1/8]
75 [165]
3.0 [6 lbs 10 oz]
0.87 (FV50S) [28]
Outdoor : D.B. 35:(95°F), W.B. 23.9:(75°F)
Outdoor : D.B. 8.3:(47°F), W.B. 6.1:(43°F)
Outdoor : D.B. -8.3:(17°F), W.B. -9.4:(15°F)
Outdoor intake air temperature
D.B. 46:(115°F)
D.B. -18:(0°F)*
D.B. 21.1:(70°F), W.B. 15:(59°F)
D.B. -11.1:(12°F), W.B. -12.2:(10°F)
PCA-A36KA
PUZ-A36NHA3
PUZ-A36NHA3-BS
35,000
35,000
12,000
4630
7.6
14.4
8.5
0.73
38,000
37,000
12,000
3190
3.40
10.2 / 8.1
25,000
2800
2.62
30
AC 208 / 230V
DC24V
DC12V
15
22-24-26-28
20-22-24-26
775-850-920-990
705-775-850-920
0
37-39-41-43
1600 [63]
680 [26-3/4]
230 [9-1/16]
36
79
26 [1-1/32]
Attached in Indoor Unit
25
40
17.5
Linear Expansion Valve
Reverse Cycle
Ivory Munsell 3Y 7.8/1.1
950 [37-3/8]
330+30 [13 + 1-3/16]
R410A
15.88 [5/8]
9.52 [3/8]
Max. 30m [Max. 100ft]
Max. 50m [Max. 165ft]
Not Supplied
Flared
PCA-A42KA
PUZ-A42NHA3
PUZ-A42NHA3-BS
42,000
42,000
18,000
4110
10.2
15.8
11.7
0.69
48,000
45,000
18,000
3830
3.44
10.2 / 8.3
30,000
3820
2.30
2
0.97
160
23-25-27-29
21-23-25-27
810-885-955-1025
740-810-885-955
39-41-43-45
38
84
26
0.4 + 0.4
86 + 86
ANV33FDPMT
20
27.5
100 [3,530]
51
55
1350 [53-1/8]
118 [260]
4.5 [10 lbs]
1.4 (FV50S) [45]