Electronic Flame Controller ERS 01
GB - Operation and Maintenance Manual
2
Electronic Flame Controller ERS 01
GB
- Before use, please read "General use and maintenance manual" carefully.
The manuals which are enclosed with the product must be kept throughout the product's entireservice life.

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul ERS 01

  • Page 1 Electronic Flame Controller ERS 01 GB - Operation and Maintenance Manual Electronic Flame Controller ERS 01 - Before use, please read ”General use and maintenance manual” carefully. The manuals which are enclosed with the product must be kept throughout the product’s entireservice life.
  • Page 2: Table Of Contents

    ENGLISH Table of contents List of drawings Fig. 01 Function diagram ........... 4 General information ........3 Fig. 02 Method of opening the casing ......4 Technical data ..........3 Fig. 03 Installing the regulator on a wall ...... 4 Operation safety ..........4 Fig.
  • Page 3: General Information

    Jøtul and Scan fireplaces and fireplace inserts. The Electronic Flame Controller has also been equipped with Table of temperature measurement accuracy Uni 270 software which enables the use of ERS 01 with Internal structure: K-type thermocouple any fireplace equipped with an external combustion air Accuracy: ±1% of range...
  • Page 4: Operation Safety

    3.0 Operation safety 4.0 Assembly The regulator can only be used in a household and similar The regulator is designed to be used in the environment in facilities. which, at most, dry conducting contamination can occur (2 level Before starting the assembly, repairs or maintenance, as well as of contamination according to PN-EN 60730-1).
  • Page 5: Fig. 04 Regulator Interior With Terminals

    (with a collet) and releasing the button. 4.2.3 Temperature sensor installation The ERS 01 regulator cooperates with K-type thermocouples. Measurement range of supplied exhaust gases sensor is 50÷1150°C; the sensor should be installed on a flue where the exhaust gasses come out of the fireplace.
  • Page 6: Fig. 07 Handling Clamping Terminals

    Sensor cables should be connected according to colors on the picture. Connecting the sensor in reverse way will cause indication errors. If, during ignition of the fireplace, the temperature of exhaust gases reaches app. 100°C, the regulator will report an alarm of incorrect connection of the sensor no.
  • Page 7: Closing The Casing

    5.0 Closing the casing rotate the knob to change the values. To confirm the value, click the button again. This action moves the cursor to another position in the menu. To confirm the log-in, press OK. To reject In order to close the casing, fasten the cover by inserting its the log-in, press CANCEL.
  • Page 8 tP-PID - Time interval at which the throttle will be set. T% lighting I – optimum level of throttle opening which is reached when the no actions of any PID segments have Decreasing the value of this time stabilizes the object but any influence on the throttle (value added at the end of PID shortens service life of the throttle.
  • Page 9: Typical Malfunctions Of The System

    7.0 Typical malfunctions of the system Symptoms What to do The flame controller’s display is 1. set the display contrast in MENU/handling/display unreadable 2. set the display brightness in MENU/handling/display The flame controller does not signal Set the alarm sounds and volume in MENU/handling/sound the shortage of fuel spite reaching...
  • Page 10: Operating The Regulator

    8.0 Operating the regulator operation, press any other button on the remote control (for adapted remote control it must be one of the adapted buttons). In order to switch between device operation modes, press the The regulator is equipped with TOUCH&PLAY system which operation mode switch button;...
  • Page 11: Regulator Menu

    The following actions are available with the use of remote After activating MENU, a screen with icons of the regulator control according to the operation mode: functions will be displayed: Buttons for Buttons for changing the changing throttle preset temperature of position exhaust gases Ignition...
  • Page 12: Regulator Operation Modes

    Fig. 24 Preset temperature positions Presetting temperature Temperatures in the ERS 01 regulator are preset directly from Presetting throttle opening the main window or via menu system. 10.0 Regulator operation...
  • Page 13: Fig. 25 Operating Modes Icons

    ENGLISH 10.1.2 “Lighting” - phase II In the second phase of lighting, flame controller slowly shuts the throttle so that the exhaust gas temperature reaches the temperature of automatic operation parameters. When the exhaust gas temperature levels with the preset Fig.
  • Page 14: Alarms

    ENGLISH The stage is terminated when: • the exhaust gas temperature value decreases below Toperation (phase III initiated) • the flame controller detects an increase of the exhaust gas temperature and returns to phase I, continuing combustion process. Fig. 29 Operation screen in “Manual” mode 11.0 Alarms Fig.
  • Page 15: Options Menu

    ENGLISH 12.1 Burning options Code 02; alarm “Tc sensor damage” This alarm is reported when a temperature on exhaust gas sensor exceeds 1115°C. It indicates that a measurement range of both sensor and regulator is exceeded Code 03; alarm “Tc connection error” This alarm will be reported when the exhaust gases temperature sensor (thermocouples) is connected incorrectly.
  • Page 16: Fig. 31 Operation Of Fuel Shortage Detection

    ENGLISH 12.2 Fuel shortage detection The regulator is equipped with a fuel shortage detection function. This function can be active only in automatic Fig. 31 Operation of fuel shortage detection operation mode. Principal of operation of fuel detection is the following: when as a result of burning, the temperature drops in relation to a preset temperature by value of dT fuel shortage parameter, the regulator will enable a differentiate algorithm and will test the...
  • Page 17: Fig. 33 User Log-In Screen

    ENGLISH When the throttle calibration menu is enabled, the intake air throttle will be closed automatically. Position a cursor on the throttle icon and push the regulator knob. Corrected value starts blinking. By turning the knob, move the throttle left or right. It is possible to correct throttle position within a range of ±7°.
  • Page 18: Handling Menu

    ENGLISH 13.0 Handling menu 13.2 Handling\Screen menu This menu is dedicated to the user. It enables to make basic changes in regulator handling. This menu provides access to set screen options. Turning the knob will result in switching between fields of backlight and contrast settings.
  • Page 19: Disabling

    ENGLISH 14.0 Disabling Switches the regulator off. When this menu is selected, a question whether to switch the regulator off is displayed. Fig. 36 Sound options screen Volume settings are made similarly as contrast and backlight settings. Disabling confirmation of knob movement by a sound signal Fig.