4.2.6 Removal of Carriage Unit and Carriage Shaft A/B

1.
Remove the Main Board
Cover.(Refer to 4.2.5 Removal of Main Board Step 2 to
Step 5.)
2.
Remove the Carriage FFC (2 pcs) from the Main Board Connector.
3.
Remove the Carriage FFC Fixing Sheet from the notches of the Cover A.
Carriage FFC
Main Board
Figure 4-18. Removal of Carriage FFC and FFC Fixing Sheet
4.
Remove the one screw (CBP, M3x10) that are securing the FFC Fixing Plate.
5.
Slide the FFC Fixing Plate in the direction of the arrow and lift it, then pull the
Carriage FFC (2 pcs) out from the plate and remove the FFC Fixing Plate.
M3x10
(50±10Ncm)
FFC Fixing Plate
Figure 4-19. Removal of FFC Fixing Plate
When reinstalling the FFC Carriage, be sure to put it through the
Ferrite Core.
DISASSEMBLY/ASSEMBLY
FFC Fixing Sheet
Notch
Cover A
Ferrite Core
Disassembly Procedure
6.
Remove the two-sided tape which is stuck to the Carriage FFC from the Cover A, and
pull the Carriage FFC out from the Main/Power Supply Board Bracket.
Sticking position of two-sided tape
Figure 4-20. Removal of Carriage FFC
7.
Move the Carriage Unit to the notch position shown in the following figure.
Housing Lower
Figure 4-21. Moving the Carriage Unit
Revision A
Main/Power Supply Board Bracket
Carriage Unit
Notch
44