Navien NCB-150E Service Manual page 45

Ncb-e condensing water heaters
Table of Contents

Advertisement

Item
(J) Heat Capacity
(K) Flame State
(L) Target RPM
(M) Current RPM
(N) Target APS
(O) Current APS
44
NCB-E Service Manual
Description
Display of current heat capacity %
range: 50-100%
Default : 100%
Display of flame detection current
AD value
Flame ON : Below 70
Flame OFF : Over 175
Target fan motor RPM display
Current fan motor RPM display
Target APS voltage value display
Current APS voltage value display
Display
% Heat capacity display in percentage
ex) 100%,
Displays the flame by flame detection AD value (0-255) , ex) 200
Displays RPM deleting the 1st digit,
ex) 3600rpm,
Display of RPM by omitting the last digit, ex) 3600 rpm,
Display of the APS value as voltage up to the first decimal place, ex)
3.2V;
Display of the APS value as voltage up to the first decimal place, ex)
3.2V;
Version 1.4