Optical Parts Disassembly
, Locations and Directions
When mounting or assembling the optical parts in the opti-
cal unit, the parts must be mounted in the specified loca-
tion and direction as shown in figure below.
1
1
2
2
3
3
4
4
5
5
6
6
8
8
7
7
No.
Parts Name
1
Integrator lens (OUT)
Prism beam splitter (PBS)
3
Condenser lens (OUT)
4
Dichroic mirror (B)
5
Dichroic mirror (G)
6
Condenser lens (G)
7
Mirror (R)
8
Condenser lens (R)
9
Condenser lens (B)
10
Mirror (B)
The arrows in the figure indicate the mount direction
of the part for the replacement. Check the number
on the arrows and mount each part according to its
note;
A: The printed part no. comes to this side.
B: Rugged surface comes to this side.
Slit
-0-
10
10
9
9
8
8
7
7
Fig.8