Monessen Hearth ODGR400 Homeowner's Installation And Operating Manual
Monessen Hearth ODGR400 Homeowner's Installation And Operating Manual

Monessen Hearth ODGR400 Homeowner's Installation And Operating Manual

Outdoor gas fireplace

Advertisement

Quick Links

Outdoor Gas Fireplace
Models: ODGR400, ODGR500
INSTALLER/CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing
this equipment.
WARNING:
For Outdoor Use ONLY.
Homeowner's Installation and
Operating Manual
7114
ODGSR
cover
11/03
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
C E RT I F I E D
92D0001 5/09 Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Monessen Hearth ODGR400

  • Page 1: Safety Information

    Outdoor Gas Fireplace Models: ODGR400, ODGR500 INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    ODGR Series Outdoor Gas Fireplace Thank you and Congratulations on your purchase of a MHSC fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Installation & Operating Instructions

    This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S.A Installations follow local codes and/or the cur- rent National Fuel Gas Code. ANSI Z223.1/NFPA 54. In the Commonwealth of Massachusetts, all gas fittings and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1. This appliance gives off high temperatures and should be located out of high traffic areas and away from furniture. 2. Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing. 3. Children should be carefully supervised when they are in the same room as your appliance. 4. Under no circumstances should this appliance be modified. Parts having to be removed for servicing should be replaced prior to operating this appliance again. 5. Installation and any repairs to this appliance should be car- ried out by a qualified service person. A professional service person should be contacted to inspect this appliance an- nually. Make it a practice to have all of your gas appliances...
  • Page 4: Fireplace Dimensions

    ODGR Series Outdoor Gas Fireplace 48 " (1232mm) " (13mm) " (822mm) " 39 " (1007mm) Low Voltage Wire Access Fig. 1 ODGR400 specification and framing dimensions. 50" (1270mm) " (13mm) 35 " (895mm) " 39 " (1007mm) Fig. 2 ODGR500 specification and framing dimensions. Fireplace Dimensions " (559mm)
  • Page 5: Moisture Resistance

    Moisture Resistance This outdoor fireplace will shed moderate amounts of water, but is not waterproof. Water and condensing wa- ter vapor may enter the chase under certain conditions. The fireplace will not perform as an exterior wall. Mois- ture penetration must be considered for construction that places the fireplace in structure walls or on mois- ture sensitive surfaces. When installed on exterior walls: MHSC recommends the fireplace chase be constructed outside the struc- ture's weather envelope. Where the platform meets the wall, use a flashing detail similar to that required for attached decks. Chase platforms, including hearths should slope away from the structure at 1/4 in per foot. The fireplace can be shimmed level. When installed on surfaces where water may collect or cause damage: MHSC recommends a slope of 1/8 in to 1/4 in per foot towards the drain port suggested. The fireplace can be shimmed level. Hearths should slope away from the front of the fire- place and chase at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of any combustible hearth materi- als used for moisture management. Screened Porch Installation The ODGR may be installed safely and is design certi- fied by CSA to be installed in a screened porch with these guidelines: Minimum porch area ...96 sq. feet (9 sq m) Minimum celing height ... 92" (234 cm) Minimum of two (2) walls must be screened Minimum top of screen height, side walls ...6'6" (198 cm) Minimum screen area ...64 sq. feet (6 sq m) Clearance to Combustibles Appliances Top ...0” (0 mm) Bottom .
  • Page 6: Moisture Resistance

    ODGR Series Outdoor Gas Fireplace Black Mantel Surround Face CFM164 Side of CFM164a Combustion Chamber Mantel Leg Chart 06/22/01 sta Ref. Mantel Ref. Leg Depth of Comb. Opening 14" (356 mm) CFM170 12" (305 mm) DV Builder Front View 10" (254 mm) 8" (203 mm) 1¹⁄₂" (38 mm) Fig.
  • Page 7: Gas Specifications

    Natural Minimum Inlet Pressure 5.5” w.c. Maximum Inlet Pressure 14.0” w.c. Manifold Pressure 3.5”w.c. ODGR400 / ODGR500 Certified to CSA 4-96 High Elevations Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370 m) above sea level.
  • Page 8: Exterior Chase Installation

    ODGR Series Outdoor Gas Fireplace Nailing Flange Valve Access Panel FP1416 Fig. 8 Parts identification. FP1416 Interior sides of an exterior chase ODUVSR should be weather proof part id 11/24/03 djt Valve Access Panel Nailing Flange Fig. 9 Exterior chase installation. FP1416 ODUVSR part id 11/24/03 djt *Do not install header until unit is in place. This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa). Standoff Surround The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during Gas any pressure testing of that system at test pressures in Line Ac-...
  • Page 9: Remote Wall Switch

    Remote Wall Switch NOTE: Use an approved outdoor switch. 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insu- lation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box. 2. Attach wire to switch and install switch into receptacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. Refer to Figure 11. CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply. For lighting instructions, refer to Page 12. NOTE: If glass doors are installed, the unit must be operated with the doors fully open.
  • Page 10: Operating Instructions

    3. Carefully place Ember Log between grate and burner. (Figs. 13 & 14) 4. Place the front of right rear log on the burner and the back of the log on the rear log support. 5. Place the top logs onto the locator notches. Ensure the logs are secure. (Fig. 13 & 14) Left Cross Left Rear Log Left Ember LG318 Fig. 14 ODGR500 log placement. Operating Instructions Right Cross Left Cross Left Rear Fig. 13 ODGR400 log placement. Middle Cross Log Upon completing the gas line connection, a small amount of air will be trapped in the line. When Right Cross first lighting the unit with pilot light, it will take a few minutes to purge the trapped air. Once purg- ing is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the appliance will not require purging. Right Rear When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may con- Log Right Ember dense and fog the glass; this moisture disap- pears in a few minutes of burning.
  • Page 11: Flame Adjustment

    Fig. 15 Flame adjustment knob for SIT820 valve. Flame Characteristics FP390 FLAME ADJUSTMENT KNOB It is important to periodically perform a visual check of 11/21/96 the pilot and the burner flames. Compare them to the il- lustrations below (Figs. 16, 17, 18). If any of the flames appear abnormal call a service person. Red Glow Fig. 17 ODGR400 flame appearance. Fig. 18 ODGR500 flame appearance. 92D0001 Turn clockwise to lower flame height Fig. 16 Proper pilot flame height. LG319 ODUVSR36 log flames 11/24/03 djt ODGR Series Outdoor Gas Fireplace 3/8"-1/2"...
  • Page 12: Optional Weather Enclosures

    Screen Rail Fig. 19 Place top of weather enclosure between surround top and screen rail. KT457 place we top 4/1/04 djt Screen Hearth Brick Fig. 20 Push bottom of weather enclosure into firebox. KT458 place we bottom 4/1/04 djt An optional stainless steel hood is available for both the ODGR400 and ODGR500. Installation Instructions: 1. Turn the unit off and allow to cool. 2. Place the hood so the 2B⁄," (67 mm) slot clears the sensor plate located under the fireplace opening on the top left side. (Fig. 21) 3. Secure the hood to the unit using the three (3) slots in the hood and the pilot holes in the unit with the stainless steel sheet metal screws provided. (Fig. 21) 4. Align the sides of the hood so the pilot holes on the right and left sides of the unit are exposed through the slots on the ends of the hood. Secure using the Surround Top remaining stainless steel sheet metal screws. (Fig.
  • Page 13: Lighting & Operating Instructions

    Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 14: Troubleshooting

    ODGR Series Outdoor Gas Fireplace Nova SIT 820 Standing Pilot START Gas Supply On Pilot Lights with Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner System OK Troubleshooting CHECK Supply Line Hooked up Shutoff Valve Open Lockout has engaged. Wait 60 seconds and try again.
  • Page 15: Maintenance

    Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use. Cleaning There are three methods of cleaning the polished stain- less steel of your outdoor fireplace; 1. Warm, soapy water - to loosen any dirt film 2. Glass cleaner with ammonia 3. Stainless steel cleaner available at hardware stores Regardless of which method is used, remember that anything with too much abrasive may dull the finish.
  • Page 16 ODGR Series Outdoor Gas Fireplace 1. ODGR400 Logs 18a/b MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODGR400, ODGR500 Ref. Description 1. Logs - Complete Set 1a. Log - Left Rear 1b. Log - Right Rear 1c. Log - Right Cross 1d. Log - Left Cross 1e. Log - Middle Cross 1f. Log - Left Ember 1g. Log - Right Ember 1h. Front Ember Log 2. Burner Housing Assembly 3. Ceramic Tile (single) 4a. Burner Orifice - Natural (Manifold & Orifice) 4b. Burner Orifice - LP (Manifold & Orifice) 6. Side Brick - Left* 7. Back Brick*...
  • Page 17: Replacement Parts

    ODGR400, ODGR500 Ref. Description 14. Pilot Tubing 15. Cable Ignitor 24" 16. Thermocouple 24" 17. Grate 18a. Pilot Orifice - Natural 18b. Pilot Orifice - LP 19a. Valve NOVA - Natural 19b. Valve NOVA - LP 20a. Air Shutter - Natural 21. Hearth Brick Cover 22. Thermodisk 23. Conversion Kit LP to Natural 24. Conversion Kit Natural to LP 25. Valve Access Panel Assy * When ordering replacement firebrick, check the serial number and plant code of the fireplace, located on the UL label inside the firebox. Serial numbers/plant code with a 'P' require the firebrick listed first under the respective fireplace (white brick). Serial numbers/plant code with an 'X' require the firebrick listed second under the respective fireplace (grey brick). Contact MHSC for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Monessen Fireplaces distributor or dealer. You will need the following information when ordering re- placement parts: 1. The appliance model number.
  • Page 18: Accessories

    ODGR Series Outdoor Gas Fireplace The following accessories are available from your local Majestic Fireplaces distributor. Each accessory comes with a separate installation instruction for mounting to the particular firebox. Be sure to read each instruction thoroughly before installing. Accessory 4" Stainless Steel For heater up to 40,000 BTU's and mantels Hood 8" high by 12" wide Glass Doors Designed to enhance the look of the fireplace Weather Enclosure Designed to protect the burner when unit is not in use Drain Pan Designed to be installed under unit to shed water by means of containing and piping way from structure CAUTION: This firebox is a highly engineered system, and, as such, must be operated only with MHSC ap- proved components. If you use an unapproved component to make any modifications, you may create a pos- sible fire hazard and will void the MHSC warranty.
  • Page 19: Warranty

    What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase. Ten-Year Coverage: From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use, MHSC will make available to you, at our factory, a free replacement for any defective part in this fireplace or accessory. Twenty-Five-Year Availability of Replacement Parts: From the eleventh through the twenty-fifth year following the date this fireplace or accessory is first purchased for use, MHSC will make available at our factory replacement parts for this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received. What is Not Covered • This limited warranty does not cover: • Transportation or shipping cost. • The cost of a service call to diagnose trouble. • Painted surfaces. • Damage or defect caused by improper installation, accident, misuse, abuse or alteration. • Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure dif- ferentials produced by wind. • Broken glass components.
  • Page 20 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

This manual is also suitable for:

Odgr500