Safety Advice; Technical Data - Moffat U21321 GSV 5050 W Operating And Installation Instructions

Electrolux gas cooker operating instructions
Table of Contents

Advertisement

SAFETY ADVICE

Before installation ensure that the local
distribution conditions (gas type and
pressure) and the pre-setting of the
appliance are consistent.
This appliance must be installed only in
a room with good ventilation.
This appliance must not connected to a
flu. It has to be installed and connected
in accordance with the rules in force.
Special attention should be paid to the
applicable
disposal
ventilation.
The adjacent furniture panels have to
be heat proof or protected by such
material.
The
adjusting
appliance are mentioned on the rating
plate.
Connection to gas supply.
Check that the gas flow and the diameter of
the supply pipe is sufficient to supply all the
appliances of the installation.
Check that all connections are tight.
Install an accessible and visible gas
tap to isolate the appliance.
Normal
Burner
power
(kW)
RAPID
2.60
SEMI-
2.00
RAPID
AUXILIARY
1.00
OVEN
3.20
GRILL
1.80
17
INSTRUCTIONS FOR THE INSTALLER
concerning
conditions
of
this

TECHNICAL DATA

Table no.1
(Cat : II
Economic
By-
Gas Type
power
pass
(kW)
(mm)
Natural Gas
0.72
0.42
Butane
Propane
Natural Gas
0.43
0.32
Butane
Propane
Natural Gas
0.35
0.29
Butane
Propane
Natural Gas
1.00
0.46
Butane
Propane
Natural Gas
-
-
Butane
Propane
Installation of flues and ventilation
-
for gas appliances of rated input not
exceeding 60 kW (1
family gases) – Part 2 Specification
for installation of ventilation for gas
appliances – BS 5440;
-
Gas burning appliances – Part 3
Domestic
cooking
burning gas – BS 5386;
-
Specification for installation of low
pressure gas pipe work of up to
20mm (R1) in domestic premises (2
family gas) – BS 6891;
Pipe threads for tubes and fittings
-
where pressure-tight joints are made
on the threads (metric dimensions) –
BS 21: 1985;
-
Flexible
hoses,
sockets for gas burning appliances –
BS 669;
Installation of domestic gas cooking
st
nd
appliances (1
, 2
and 3
– BS 6172: 1990;
)
2H3+
Nozzle
Pressure
diameter
(mbar)
(mm)
20 mbar
28-30mbar
37mbar
20 mbar
28-30mbar
37mbar
20 mbar
28-30mbar
37mbar
20 mbar
28-30mbar
37mbar
20 mbar
28-30mbar
37mbar
st
nd
rd
, 2
and 3
appliances
nd
end
fittings
and
rd
family gases)
Cons
3
m
/h
g/h
1.12
0.248
0,86
188,8
0,86
0.96
0.191
0,71
145,2
0,71
0.70
0.093
0,50
72,6
0,50
1.30
0.305
0,88
232,4
0,88
1.00
0.172
0,67
130,7
0,67

Advertisement