Download Print this page

Adjustment - Kenwood 1060CD Service Manual

Multiple cd player
Hide thumbs Also See for 1060CD:

Advertisement

1060CD/1070CD/DP-R6090/R7090/D-R350
No.
ITEM
Step 1~4 are in TEST MODE
1
LASER POWER
TRACKING ERROR
2
BALANCE
FOCUS ERROR
3
BALANCE
4
TRACKING GAIN
Note:
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.
LPF: Around 47 kΩ+ 390 pF or so.
(a) Laser power
Pickup
4

ADJUSTMENT

INPUT
OUTPUT
SETTINGS
SETTINGS
Apply the sensor section
of optical power meter
on the pickup lens.
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : TE (CN2 pin 6)
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : FE (CN2 pin 2)
Test disc
Type 4
Connect a LPF to CN2
Apply signal of
pin 5-6 to which you
1.2 kHz,
connect an oscilloscope
50mVrms to
or AC voltmeters.
CN2 pin 5-6.
0.08~0.15 mW
Optical power meter
PLAYER
ALIGNMENT
SETTINGS
POINTS
While pressing the
RANDOM key, turn
the AC ON. (Test
mode) Press the
PLAY/PAUSE key,
then confirm that the
display is "03".
Press the
PLAY/PAUSE key,
TE BALANCE
then confirm that the
VR2
display is "03".
Press the
PLAY/PAUSE key,
FE BALANCE
then confirm that the
VR1
display is "05".
Press the
TRACKING
PLAY/PAUSE key,
GAIN
then confirm that the
VR3
display is "05".
(e) Tracking gain
CN2
1
2
3
_
4
1.2 kHz
5
50 mVrms
6
+
7
ALIGN
FIG.
FOR
On the power from
0.08 to 0.15 mW,
when the diffraction
grating is correctly
(a)
aligned with the RF
level of 1.0 Vp-p or
more.
Symmetry between
upper and lower pat-
terns
Optimum eye pattern
Two VTVMs should
(e)
read the same value.
GND
+
L.P.F.
VTVM
+
L.P.F.
VTVM

Hide quick links:

Advertisement

loading

This manual is also suitable for:

R7090D-r3501070cdDp-r6090