Power LED blinking timing chart

1.
Subject
Information of LED Flashing timing chart.
2.
Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Once
1
3
4
5
6
8
Blinking timing
4 sec
Light
No Light
Contents
Inverter SOS
BT_30V, SOUND 18V,
PANEL 12V
SUB 9V
SUB 5V
MAIN 9V
MAIN 3,3V
11
Check point
POWER UNIT
LCD PANEL
AP BOARD, H BOARD
AP BOARD, H BOARD
DG BOARD
AP BOARD, H BOARD
DG BOARD
AP BOARD, DG BOARD
AP BOARD, H BOARD
DG BOARD

Hide quick links: