Whirlpool AWM 8000 Service Manual page 3

Table of Contents

Advertisement

S E R V I C E
Technical data
Floater
Nominal current
Nominal power
Switch energy
Drain pump (synchronous)
Nominal voltage
Nominal current
Nominal consumption
Frequency
Resistor (coil)
Motor protection
Capacity (1.25m height)
Flowmeter
Nominal voltage
Nominal current:
nominal
maximal
Pressure area
Line to be recognized
Frequency signal
Distribution actuator
Motor:
Nominal voltage
Nominal current
Nominal resistance(20˚C) 6.5 ± 10% kΩ
Contacts:
Nominal current
Nominal voltage
Electronic complete
Basic
Programmed
Nominal voltage
Frequency
Detergent Dispenser
Programmes
Cold fill
Flowmeter
Speed
Ambient temperature
Storage temperature
Whirlpool Europe
Customer Service
5
V DC
~1
mA
< 15
cN
220(-15%)-240(+6%) V
0.35
A
45
W
50 ± 3
Hz
98 ± 7%
yes
31 ± 2
l/min
5
V
1
mA
20
mA
0.5 - 10
bar
195 - 215
pulse/l
3.25 - 36
Hz
230 +10%, -15% V
13
mA
1
mA
24
V
4619 702 10481
4619 702 14041
230
V
50
Hz
3 Chambers
12
yes
yes
1400
rpm
up to 70
˚C
up to 85
˚C
AWM 8000-CENTR.EU
8570 079 10000
Program
1.
2.
3.
4.
5.
6.
7 .
8.
9.
10.
11.
12.
Output
Aquastop (activated) AQ2.2 - (Vcc)
Pump (on)
Valve cold (on)
Valve hot (on)
Heating (on)
Motor distributor (on) DI6.1- DI6.3
Pressostat
- empty
- full(L1)
Motor
Type
Resistance contacts:
1 - 2
1 - 3
2 - 3
4 - 5 (Tachometer)
Radio interference supression
Nominal voltage
Nominal capacity
Nominal inductance
Nominal resistance
Motor control unit (MCU)
Fac. code
Supply
23.08.2002 / Page 3
Doc. No: 4812 712 17818
White cotton
Coloured cotton
Easy care
Daily load 40˚
Rapid plus
Delicate
Wool
Handwash
Drain
Gentle spin
Spin
Rinse & Spin
24 V
DP2.1 - DP .2.2
230 V
VCH7 .1 - VCH7 .3 >170 V
VCH7 .5 - VCH7 .7 > 170 V
HE2.1 - HE2.2
230 V
230 V
PR6.4 - (Vcc)
24 V
PR6.6 - (Vcc)
24 V
PR6.5 - (Vcc)
24 V
CIM 2/55-232/WHE1
i = 1:12.1
Ω ± 7%
3.4
Ω ± 7%
3.4
Ω ± 7%
3.4
Ω ± 7%
115.4
230
V
1 µ F X1 + 2 x 0.22 nF Y
2 x 1
mH
470
kΩ
4619 703 10611
L and N
230 V/50 Hz