Electrical Tests For Electric Dryers - Electrolux EIGD55H Technical & Service Manual

Wave-touch & iq-touch front-load dryer
Hide thumbs Also See for EIGD55H:
Table of Contents

Advertisement

Troubleshooting
Electrical Tests For Electric Dryers Only
High Limit Thermostat Cycle Time
Trip:
Run the following test at room temperature. Set Time Dry cycle for 30 minutes and the heat selection at maximum
setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door
switch held closed by tape or similar means. The thermostat must open (heater off) between 35 to 120 seconds.
Reset:
When the exhaust block is removed and the door closed (keep tape over door switch), the thermostat must reset
(heat on) within 120 seconds.
Thermal Limiter Trip Time
Run the following test at room temperature. Set Time Dry cycle for 30 minutes and the heat selection at maximum
setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door
switch held closed. The thermal limiter should trip and shut off the heaters after 1 to 5 minutes of operation. To
enable this test, the High Limit Thermostat must be bypassed and NTC2 should be removed from the heat duct.
NOTE: This test renders the thermal limiter inoperative, a new thermal limiter must be installed after this test.
Drum Temperatures
The following tests should be run with an unrestricted exhaust. The location of the thermal couple is to be the
square in the lint grill which is 12 squares left from the right edge of the lint blade and (2) squares
forward. The tip should extend 1.25" into the air grill. Set the dryer timer as needed for each test. The recordable
temperature is to be the maximum temperature following the heater off of the 3rd cycle.
No load is to be used for the following heat settings:
Heat Setting
Thermistor Status
Max*
Satisfied/Heater Off
Medium*
Satisfied/Heater Off
Low*
Satisfied/Heater Off
* Each opening temperature should be equal to or higher than the opening temperature for the next lower tempera-
ture setting.
Temperature (F)
120 to 160
110 to 140
95 to 130
5-4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewed65hEied55hEwgds65hEwmed65hEwmgd65h

Table of Contents