Features And Specifications - IBM eserver xSeries 220 Type 8648 Installation Manual

Table of Contents

Advertisement

Features and specifications

Table 1 provides a summary of the features and specifications for your server.
Microprocessor:
®
®
Intel
Pentium
III
microprocessor with MMX
technology and SIMD extensions
256 KB or 512 KB ECC, Level-2
cache
133 MHz front-side bus (FSB)
Support for up to two
microprocessors
Memory:
Standard: 128 MB or 256 MB
Maximum: 4 GB
Type: 133 MHz, ECC, SDRAM,
registered DIMMs
Slots: Four DIMM connectors,
noninterleaved
Drives standard:
Diskette: 1.44 MB
CD-ROM: 20X - 48X IDE
Supports hot-swap SCSI hard
disk drives (some models)
Expansion bays:
Two 5.25-in. bays (one CD-ROM
drive installed)
Two 3.5-in. bays (one diskette
drive installed)
Three 3.5-in. slim bays available
in drive cage (some models have
a hard disk drive installed)
PCI expansion slots:
Three 64-bit/33 MHz
Two 32-bit/33 MHz
Power supply:
One 330 watt autosensing (115-230 V
ac)
Table 1. Features and specifications.
2
xSeries 220: Installation Guide
Video:
S3 video controller (integrated
on system board)
Compatible with SVGA and VGA
8 MB SDRAM video memory
Size:
Height: 470 mm (18.5 in.)
Depth: 508 mm (20 in.)
Width: 165 mm (6.5 in.)
Weight: approximately 19.5 kg
(43 lb) when fully configured or
15.9 kg (35 lb) minimum
Integrated functions:
Ultra160 SCSI low voltage
differential (LVD) controller
One 10BASE-T/100BASE-TX
Intel Ethernet controller on the
system board with Wake on
®
LAN
support
Automatic BIOS Recovery
(ABR)
Automatic Server Restart (ASR)
Two serial ports
Parallel port
Two Universal Serial Bus (USB)
ports
Keyboard port
Mouse port
IDE controller port
Video port
Acoustical noise emissions:
Sound power, idling: 5.9 bel
maximum
Sound power, operating: 6.1 bel
maximum
Environment:
Air temperature:
— Server on: 10° to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914
m (2998.7 ft)
— Server on: 10° to 32° C (50.0°
to 89.6° F). Altitude: 914 m
(2998.7 ft) to 2133 m (6998.0
ft)
— Server off: 10° to 43° C (50.0°
to 109.4° F). Maximum
altitude: 2133 m (6998.0 ft)
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 341 Btu
(100 watts)
Maximum configuration: 1604 Btu
(470 watts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA),
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents