Table 1 provides a summary of the features and specifications for your server.
Microprocessor:
®
®
•
Intel
Pentium
III
microprocessor with MMX
technology and SIMD extensions
•
256 KB or 512 KB ECC, Level-2
cache
•
133 MHz front-side bus (FSB)
•
Support for up to two
microprocessors
Memory:
•
Standard: 128 MB or 256 MB
•
Maximum: 4 GB
•
Type: 133 MHz, ECC, SDRAM,
registered DIMMs
•
Slots: Four DIMM connectors,
noninterleaved
Drives standard:
•
Diskette: 1.44 MB
•
CD-ROM: 20X - 48X IDE
•
Supports hot-swap SCSI hard
disk drives (some models)
Expansion bays:
•
Two 5.25-in. bays (one CD-ROM
drive installed)
•
Two 3.5-in. bays (one diskette
drive installed)
•
Three 3.5-in. slim bays available
in drive cage (some models have
a hard disk drive installed)
PCI expansion slots:
•
Three 64-bit/33 MHz
•
Two 32-bit/33 MHz
Power supply:
One 330 watt autosensing (115-230 V
ac)
Table 1. Features and specifications.
2
xSeries 220: Installation Guide
Video:
•
S3 video controller (integrated
™
on system board)
•
Compatible with SVGA and VGA
•
8 MB SDRAM video memory
Size:
•
Height: 470 mm (18.5 in.)
•
Depth: 508 mm (20 in.)
•
Width: 165 mm (6.5 in.)
•
Weight: approximately 19.5 kg
(43 lb) when fully configured or
15.9 kg (35 lb) minimum
Integrated functions:
•
Ultra160 SCSI low voltage
differential (LVD) controller
•
One 10BASE-T/100BASE-TX
Intel Ethernet controller on the
system board with Wake on
®
LAN
support
•
Automatic BIOS Recovery
(ABR)
•
Automatic Server Restart (ASR)
•
Two serial ports
•
Parallel port
•
Two Universal Serial Bus (USB)
ports
•
Keyboard port
•
Mouse port
•
IDE controller port
•
Video port
Acoustical noise emissions:
•
Sound power, idling: 5.9 bel
maximum
•
Sound power, operating: 6.1 bel
maximum
Environment:
•
Air temperature:
— Server on: 10° to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914
m (2998.7 ft)
— Server on: 10° to 32° C (50.0°
to 89.6° F). Altitude: 914 m
(2998.7 ft) to 2133 m (6998.0
ft)
— Server off: 10° to 43° C (50.0°
to 109.4° F). Maximum
altitude: 2133 m (6998.0 ft)
•
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
•
Minimum configuration: 341 Btu
(100 watts)
•
Maximum configuration: 1604 Btu
(470 watts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
•
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
•
Input kilovolt-amperes (kVA),
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA