Download Print this page

Technical Data - Whirlpool AWT 2274 Service Manual

Advertisement

08.08.2001 / Page 2
Doc. No: 4812 712 16566

Technical data

Dimensions
Height
Width
Depth
Weight
Net weight
With packing
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Speed spinning max.
Capacity of dry laundry
Cotton/coloured laundry
Cotton rapid
Easy care
Easy care rapid
Delicate
Wool
Pressostat for washing-machine
Level 0 - PRF - anti foam
Switching point
Reset
Level 1 - PRL - washing
Switching point
Reset
Overflow - PRS
Switching point
Water column drum
Level 1 - PRL - washing
Switching point
Overflow
Switching point
AWT 2274
8561 227 10140
85.0
cm
40.0
cm
70.0
cm
~ 61
kg
~ 64
kg
V ± 10%
230
50
Hz
~ 2.3
kW
10
A
42
l
54
rpm
700
rpm
5/ 4.5
kg
3
kg
2.5
kg
1.5
kg
1.5
kg
1
kg
35 ± 5
mm Wc
15 ± 5
mm Wc
65 ± 5
mm Wc
35 ± 5
mm Wc
300 ± 20 mm Wc
50 ± 5
mmWc
285 ± 20 mmWc
Whirlpool Europe
Customer Service
Nominal current
Contacts:
11 - 12
11 - 14
21 - 12
21 - 24
21 - 26
Contactsystem:
11 - 12 - 14
21 - 22 - 24
21 - 26
Door lock
Lock time (0 - 85 ˚C)
Unlock time after 30'' on
Nominal voltage
Nominal current contacts:
4 - 5
Heating element
Kind of heating
Nominal voltage
Nominal power
Heat conductor resistance 25.8
Working temperature max. 120
Water inlet valve
Water temperature max.
Rated flow (> 1 bar)
Pressure range
Nominal voltage
Frequency
Starting voltage
Nominal current
Nominal power
Nominal resistor(20˚C)
Drain pump (synchronus)
Nominal voltage
Nominal current
Nominal consumption
Frequency
Resistor (coil)
Motor protection
Capacity (1.25m height)
S E R V I C E
0.5 - 1 mA/ 5 V DC
0.5 - 1 mA/ 5 V DC
4 (4)
A
16 (4)
A
1 (1)
A
jump contacts
jump contacts
slow action contacts
< 5''
110'' ± 50''
250
V
16 (4)
A
Tubular heating
element
230
V
2050
W
Ω ± 5%
˚C
90
˚C
8
l/min.
0.2 - 10
bar
220 - 240 V
50
Hz
170
V
40
mA
8.8
VA
kΩ ± 10%
3.8
230
V
0.3
A
34
W
50
Hz
Ω ± 7%
164
no
14
l/min

Hide quick links:

Advertisement

loading